27
WORK
11.
If the machine does not have the CDS device, move the tap lever (3) downwards and adjust the
amount of desired solution.
12.
If the CDS dosing system is present, the tap lever (3) must be opened full downwards completely
opening the flow of water. This lever should not be touched to make adjustments. To obtain the
correct dose to the brushes, use the knobs only to adjust the amount of water solution (4) and
detergent (5). See paragraph “DETERGENT ADJUSTMENT WITH CDS SYSTEM”.
13.
For Innova 2011 60 B versions, lower the brush head by turning the righthand lever (4) clockwise,
then lower the squeegee by turning the lefthand lever (5) counter-clockwise.
14.
Pressing the accelerator pedal (6 - right pedal), the machine starts moving, both the squeegee and
the brush head lower and the brushes start to turn (if the i-drive switch is on the third working
program)
15.
To perform a reversing manoeuvre, press both pedals (6 and 7), the squeegee will rise
automatically and the machine starts to move backwards
During the first meters, check there is sufficient solution and that the squeegee dries perfectly. The
machine will start working in good working order up to run out of detergent solution or until the battery is
discharged.
45.
OVERFLOW DEVICE (INNOVA2011 60 B)
The machine is not equipped with an overfill device, because the capacity of the recovery tank is greater
than the capacity of the solution tank. In extraordinary cases, there is a mechanical device (float) on the lid
that, when the recovery tank is full, shuts off the air to the suction motor intake TO protect it; the sound of
the vacuum motor will then be deeper. If this happens, raise the squeegee by turning the left-hand lever
clockwise. After about 15-25 seconds, switch off the suction motor by making a 1/4 turn of the key,
anticlockwise. Make a 1/4 turn of the key clockwise, and take the machine to the designated water
drainage area. Then proceed with emptying the recovery tank through a special drainage pipe (10). It is
good practice when restoring the level of the solution tank, to empty the recovery tank through the special
drainage pipe (10).
WARNING: during machine switch-on, do not keep the accelerator pedal
pressed down.
46.
OVERFLOW DEVICE (INNOVA2011 65-75-85 B INNOVA2011 70 S)
The machine is not equipped with an overfill device, because the capacity of the recovery tank is greater
than the capacity of the solution tank. In extraordinary cases, there is a mechanical device (float) on the lid
that, when the recovery tank is full, it shuts off the air to the suction motor intake protecting it, in this case
the sound of the suction motor will be deeper. In this case, turn the working knob to transfer (movement of
the machine without working), and the engine turns off after about 15-25 seconds. Then proceed with
emptying the recovery tank through a special drainage pipe (10).
It is good practice when restoring the level of the solution tank, to empty the recovery tank through the
special drainage pipe (10).