MACHINE PREPARATION
RECHARGING THE BATTERIES
Check the battery charger is suitable for the batteries installed, in terms of both
capacity and type (lead/acid or GEL and equivalents).
WARNING:
never charge a GEL battery with an unsuitable battery
charger. Follow the instructions given by the battery/battery charger
manufacturer with the utmost attention.
In order not to cause permanent damage to the batteries it is essential to
avoid their complete discharge: arrange the recharge within a few
minutes of the switching on of the flashing "discharged batteries" signal.
NOTES
: never leave the batteries completely discharged, even if the
machine is not being used.
WARNING!
For the daily recharging of the batteries, you must fully
respect the indications provided by the manufacturer or retailer. All
installation and maintenance operations must be carried out by
specialised personnel. Danger of exhalation of gas and leakage of
corrosive liquids. Danger of fire: do not go near with naked flames
BATTERY INDICATOR
The battery indicator is digital, with 4 fixed positions and a flashing one. The numbers
which appear on the display show the approximate charge level.
4
= maximum charge,
3
= 3/4 charge,
2
= 2/4 charge,
1
= 1/4 charge,
0
= discharged batteries (flashing)
WARNING!
A few seconds after the appearance of the flashing “0”, the
brush motor switches off automatically. With the remaining charge it is
possible to complete the drying process before starting the recharge.
ASSEMBLING THE SQUEEGEE
For packaging reasons, the squeegee is supplied disassembled from the machine, and
must be assembled as shown in the figure, inserting the clip into the small column of
the squeegee.
Insert the squeegee tube in the special sleeve.