99
MACHINE PREPARATION
TYPE OF BATTERY
To power the machine you can use:
two lead traction batteries with tubular plates and free electrolyte;
two airtight traction batteries with gas recombination gel technology.
Each battery consists of elements connected in series so as to provide the clamps with
a voltage of 24V.
The maximum dimensions of each battery are:
-
width: 195mm, length: 360 mm, height: 250 mm
The maximum weight of each of the two batteries is 20 kg.
To obtain a voltage of 24V, they must be connected together in series by specialised
personnel trained at the ICE Technical Assistance Centre
FITTING THE BATTERIES INTO THE MACHINE
The batteries must be housed in the special compartment beneath the recovery tank.
They should be handled using lifting equipment that is suitable in terms of both weight
and hook-up system.
They must also satisfy the requirements of Standard CEI 21-5.
To insert the batteries you must:
1. Open the recovery tank cover, bringing it forwards.
2. detach the squeegee tube (1) from the recovery tank
3. unthread the suction cap (2) by rotating it anticlockwise
4. detach the “recovery tank” drainage tube from its hook
5. remove the recovery tank
2
1
6. Position the batteries.
7. Connect the battery connector (2) to the machine connector (1).
8. Reassemble all the elements
WARNING!
All installation and maintenance operations must be carried
out by specialised personnel
2
1
CONNECTING THE BATTERY CHARGER
Beneath the recovery tank cover there is the battery connector (2), in which the battery
charger connector must be inserted. The coupling connector of the battery charger is
consigned inside the bag containing this instruction booklet, and must be assembled
on the cables of the battery charger as indicated in the instructions.
WARNING!
This process must be carried out by qualified personnel. The
incorrect or imperfect connection of the cables to the connector can cause
serious harm to people and damage to objects.