15
ABRI 820254 - 05/19 - ind. A
6. Replacing consumables
The control panel informs you:
It automatically calculates the remaining life on the basis of consumption and the time since installation.
Part numbers
:
1 SC: Q112020001
2 HP: Q112021001
3 BU: Q112022001
Alarm
:
Cartridge(s) worn (orange light + beeps).
Cartridge(s) unserviceable, require replacement (red light + beeps).
Batteries flat, require replacement (3 alternate flashing red beeps).
6.1. Handling
The filters can be replaced at any time. In order not to have water running from cartridges when replacing them,
proceed as follows:
1. Open the filter tap and leave the filtered water to run. While the water is running, cut off the water inlet
by rotating the Aquatis tap stop valve a quarter turn to the right. The valve’s fins must be perpendicular
to the pipe. A small amount of water will continue to run from the filter tap. Once the water stops running,
close the tap using the small lever that controls the filtered water.
STOP
OK
+
50 cm
27,5 cm
9 cm
•
•
•
•
•
LR6 - AA
LR6 - AA
•
•
•
•
•
BIP - BIP
1 2 3
1
2
3
1
2
3
1 2 3
1 2 3
2
3
1
OK
--
+
--
1 2 3
2. Prepare the replacement cartridge by removing it from its protective bag.
3. Remove the cartridge by rotating it a quarter turn to the left, by slotting the metal filter tool into the
indentation in the bottom of the cartridge designed for this purpose.