USER MANUAL FOR COMFLEX-6900
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 43
Figure43: MU Device - Optical Unit
Note: MU transmit optical power is -4~-2dBm.
RF Unit Management Screen
Figure44: MU Device - RF Unit
Remote Unit Management Screen
Click RU photo, users can visit RU directly. Make sure two steps are done before visit RU:
RU and MU are connected by optical fiber.
Slot number
RF parameter
Commissioning
status
Downlink input
power overdrive
alarm
Click here to ON/OFF RF switch
and modify attenuator
This part shows
MU alarm status.
Optical loss between
MU to RU.The value is
over 15dB when MU to
Ru are not connected
well.
Optical power alarm.The
indicators whill be red if the
received optical power is less
than -10dBm.
This switch for
HRU01-6900 is
OFF.
Band and Remark
information