Table 15: RU Alarms Diagnosis
Alarm condition
Diagnosis
External Alarm
Check to make sure if the external device connected is working normally
Over-
Temperature
alarm
Check device temperature on WEB GUI
If device temperature e is over threshold, make sure environment temperature
is within the envireonment temperature range that RU supported (-
40~70
℃
).Apply climatic protection to the system under severe environment.
Optical TX Alarm
Test RU transmit optical power
Replace FOU if transit optical power is less than 0dBm
Optical RX Alarm
Use Optical Power Meter to test received optical power
If received optical power is lower than -14dBm, test whether MU transmit
optical power is normal (-4~-2dBm)
Check if optical loss of fiber link is higher than 6.5dBo
Clean fiber connector with absolute ethanol
DL PA alarms
Check PA Service Status on WEB GUI RU page,
If it is [Recovery], reset PA on WEB GUI Management page, then read RU
output power: If output power is exceed threshold, need to reduce gain or
input power; if output power is normall, check whether antenna port VSWR is
too high.
If it is [Shutdown], Refer to PA Shutdown Alram
DL Output Power
Overload Alarm
Check if output power is exceed the threshold (48dBm)
Decrease the gain to reduce the output power
PA Shutdown
Alarm
Make Sure the environment temperature is -40~70
℃
Reset PA, if PA service status turns to [Recovery], and then refer to DL PA
Alarms. If PA still shutdown, the PA module maybe damaged, please contact
with Comba to replace the RU.
LNA Alarm
Uplink LNA modual damaged, please contact with Comba to replace the RU.