USER MANUAL FOR COMFLEX-5H00 1W2W
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 67
6 ALARMS AND TROUBLESHOOTING
6.1
ALARMS
Table 14: MU Alarm List
Alarm List
Alarm Condition
Over-Temperature
Alarm
Alarm when equipment temperature is higher than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold : 80
℃
by default.
Optical Tx Alarm
Alarm when Optical Transmiting power is lower than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: -7dBm by default.
Optical Rx Alarm
Alarm when Optical received power is lower than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: -10dBm by default.
DL Input Power
Overload Alarm
Alarm when DL input power is higher than the threshold, otherwise normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: 32dBm by default.
Table 15: RU Alarm List
Alarm List
Alarm Condition
External Alarm
Alarm status when the external terminals have the same H/L level with alarm
level, otherwise normal;
Alarm period: 10s by default.
Over-Temperature
Alarm
Alarm when equipment temperature is higher than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold : 80
℃
by default.
Optical Tx Alarm
Alarm When optical transmiting power is lower than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: 0dBm by default.
Optical Rx Alarm
Alarm When optical receiving power is lower than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: -14dBm by default.
PA Alarm
Alarm when any one of the PA Current Alarm,PA Over-temperature Alarm,
PA DL output power overload Alarm, Reflection Power Alarm happens,
otherwise normal;
Alarm judgment period: 3 minutes by default.
DL Output
Overload Alarm
Alarm when the DL output power is higher than the threshold, otherwise
normal;
Alarm judgment period: 3 minutes by default;
Alarm threshold: 32dBm@1W, 35dBm@2W.
Shutdown Alarm
Alarm when the PA status is off, otherwise normal;
Alarm judgment period: 10s by default.
LNA Alarm
Alarm when LNA have problems, otherwise normal;
Alarm judgment period: 3 minutes by default.