For LTE, the channel no must be LTE channel no, the bandwidth is 10, 15 or 20MHz.
The protective frequency edge interval of channels should no less than 800kHz and the minimum
interval as illustrated below.
Band A
N1
N2
Thereinto,
N1: WorkingBand A High Edge Channel No.
N2: WorkingBand B Low Edge Channel No.
Band B
600kHz
800kHz
Figure 23: The Protective Frequency Edge Interval
5.7.3 ATT
ATT adjustment includes UL/DL ATT adjustment. The purpose of adjusting the ATT is to adjust system
gain.
Figure 24: ATT
Config:
Select the required value in setting columns of RF information window for ATT, and press [Enter] or [Config]
button to finish the configuration operation.
5.7.4 ALARM THRESHOLD
Alarm Threshold includes Power threshold, Temperature threshold and VSWR threshold.
Users can set alarm threshold according to the specific situation. If the measured value is lower than the
threshold
lower limit or more than the threshold upper limit, the appropriate alarm will be generated.
The min