5 OMT
The equipment can be monitored and controlled by OMT software running on a local PC with local
commissioning cable, remote connection to the equipment via wireless GSM / CDMA network.
z
OMT software running on a local PC with serial connection to the equipment.
z
OMC (optional) software with remote connection to the equipment over wireless GSM / CDMA
network.
This chapter is to introduce how to apply local and remote connection to OMT for the first installation, for
the detailed OMT information, please refer to OMT user manual and other references.
Notice: The OMC software with remote connection to the equipment over wireless GSM / CDMA network
is optional for customers.
5.1
LOCAL AND REMOTE CONNECTIONS TO OMT
After installing OMT software on the PC, connection to the equipment can be done locally or remotely.
Double click the OMT explorer icon, the OMT Explorer main screen window will appear.
Connection via Ethernet (UDP)
In order to access to equipment via Ethernet (UDP), the PC must be set with proper IP address and
subnet mask in advance.
Figure 11
:
PC Protocol Setting
The default IP address of repeater is 195.60.16.254. To access the repeater for the first time, the PC
must be set with proper IP address: 195.60.16.X (X=1~253), subnet mask: 255.255.255.0.
After the PC protocol has been properly set, please connect the RJ45 cable to PC and equipment
Ethernet port.
Choose “Connection via Ethernet (UDP)” and click “ONLINE”.