USER MANUAL FOR RX-2620
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 26
Remote Connection to OMT
If remote connection is needed, users can select [Remote connection via modem] in connection type
window. Select desired serial port and click “OK” in [Serial Port Configuration] window to go to OMT main
window and start modem initialization. Click “connect” and the [Remote Connection] window will show
up.
Figure 14
:
Remote Connection
Config: Enter the correct phone number and click “connect”, it will be connected remotely.
Notice: Please enable the SIM card to support Circuit Switch Data.
5.2 OMT
CONFIGURATION
After entering the OMT main screen, click the “Connect” button on the toolbar, to connect the equipment
to the OMT. Successful connection will be indicated by a message “Online Ok” and equipment
parameters can be read and/or set.
Users can configure the parameters, and then offset the parameters according to desired coverage level
and interference to other BTS signals.
OMT parameters include: Common Information, RF Information, Alarm Information, and Properties
Information.
Figure 15
:
OMT Main Window
5.3 RF
PARAMETER
It is recommended to configure the following RF parameters for the first installation.