EQUIPMENT MANUAL FOR TB-1800
TB-1800 QE
Copyright - refer to title page
Page 26
ENU Status : 1-0-0
3.3.6 POLE MOUNTING DETAILS
Mount the equipment to a pole according to the following steps:
z
The equipment can be mounted on a customer-located pole of about 60~75mm in diameter.
z
Insert and tighten the U bolts (M10x85x110) to secure the mounting rack onto the pole.
z
The remainders of the installation are identical to wall-mounting.
Hex socket bolt M8x80
Nut flange
Door
Mounting Rack
Pole
U bolt M10x85x110
Rack nut
Door lock
Plain Washer 10
Nut M10
Figure 9: Pole mounting overview
3.3.7 DRIP-LOOP
It is recommended that every horizontal cable entry to the equipment forms a 'U' before its entry to the
equipment. Any accumulated water on the cable will drip down at the bottom of the loop and will not
climb up to the equipment.