Defrosting
The counter defrosts automatically with pre-set intervals. If the door to the counter is opened or the contents of
the counter is changed frequently it may become necessary to defrost the counter manually.
Pressing this key continuously for more than 3 seconds will start a manual defrosting and then return
to normal operation.
Defrosted water runs to a container placed in the compressor compartment and evaporates.
Maintenance and cleaning
Switch the cooler off at the socket.
The counter must be periodically cleaned. Clean the external and internal surfaces of the counter with a light
soap solution and subsequently wipe dry. External surfaces can be maintained using steel oil.
Do NOT use cleansers containing chlorine or other harsh cleansers, as these can damage the stainless steel
surfaces and the internal cooling system.
Clean the condenser and the compressor compartment using a vacuum cleaner and a stiff brush.
Do NOT hose the compressor compartment with water as this can cause short circuits and damage on the
electrical parts.
Service
The cooling system is a hermetically sealed system and does not require supervision, only cleaning.
If the counter fails to cool, check if the reason is a power cut.
If you cannot locate the reason to the failure of the counter, please contact your supplier. Please inform model
and serial number of the counter. You can find this information on the rating label which is placed inside the
counter in the top right hand side.
Disposal
Disposal of the counter must take place in an environmentally correct way. Please note existing
regulation on disposal. There may be special requirements and conditions which must be
observed.