6 START-UP
6.1 CLEANING INTERNAL PARTS
The appliance will have already been cleaned in the factory. However, you are advised to wash the internal parts
again before using the appliance. Make sure that the power supply cable is unplugged before carrying out the
above cleaning operation.
See cleaning and sanitizing manual for information regarding cleaning operations.
For cleaning operations in general, use an ordinary detergent for washing dishes or a solution of water and
vinegar. Rinse thoroughly with plenty of cold water and remove any ice that may have been produced during the
first 5 cycles after cleaning, together with any ice present in the bin. It is advisable to avoid using abrasive
detergents or powders, since these might damage the finish.
6.2 START-UP
When you start up the appliance the first time, or when you start it up again after a long period at a standstill,
fill the basin manually with water (Fig. 8).
This filling operation must be carried out by opening the door, raising the flaps (if any) and pouring the water
directly into the internal basin. In the cycles subsequent to the initial one, the appliance will be filled with water
in a fully automatic way.
Once the appliance has been correctly connected to the electricity mains, water mains and water drain system,
it can be started up as follows:
a) turn on the water supply tap (8 in Fig. 4)
b) insert the plug (if any) in the socket and switch on the power supply by means of the relative
switch fitted during the installation phase (7 in Fig. 4)
Switch on appliance by pressing the luminous switch (16 in Fig. 3).
For appliances that are connected permanently to the electricity mains, turn on by means of the switch on the
outside of the appliance, fitted during the installation phase.
6.2.a STARTING UP MODELS WITH CONTINUOUS DELIVERY (Fig. 9)
Carry out operations a) and b) described above; then:
•
Remove the plug (17) on the front grille panel.
•
Using a screwdriver turn the adjusting screw of the timer clockwise until you hear a click and the water
pump stops.
•
Repeat the previous operation three times consecutively at intervals of one minute each.
•
When this operation has terminated, fit the plug (17) back on the front grille; the appliance will automatically
start producing ice.
7 MAIN CAUSES OF OPERATING FAILURE
Should the appliance fail to produce ice, before calling on the Authorized Technical Service Centre, first check
carefully that:
•
The water supply tap (8 in Fig. 4), fitted during the installation phase, has been turned on.
•
Electric power is reaching the appliance; the plug (if any) is properly inserted in the socket, the switch (7 in
Fig. 4) is in the “ON” position, and the push button (16 in Fig. 3) is lighted up.