13
L1 Clamp N. 1
L2 Clamp N. 2
L3 Clamp N. 3
N Clamp N. 5
Clamp N. 6
ONCE THE ELECTRIC CONNECTION HAS BEEN PERFORMED, THE AUTHORIZED
TECHNICIAN (ELECTRICIAN) MUST ISSUE A DECLARATION CERTIFYING THE
MEASUREMENT OF THE CONTINUITY OF THE EQUIPOTENTIAL PROTECTION
CIRCUIT.
THE APPLIANCE IS TO BE SUPPLIED THROUGH A RESIBASIC CURRENT DEVICE
(RCD) HAVING A RATED RESIBASIC OPERATING CURRENT NOT EXCEEDING 30 MA
TERMINAL BOX
The terminal box is placed externally on the back of the oven.
Oven type
N. of cables
Section (mm²)
Single phase, one chamber
3
4
Single phase, two chambers and versions 9 single
phase
3
6
Three phase one chamber and two chambers
5
4
Three phase from versions 9 and up
5
6
EQUIPOTENTIAL
The equipment must be connected with an equi-potential system . the connection terminal is located near
the terminal box. The bonding wire must have a minimal section of 10 mm ².
Summary of Contents for 7482.0020
Page 1: ...1 ...
Page 24: ...24 WIRING DIAGRAMS 4 4 MEDIUM XL 3L XL 4 400V 3PH one chamber ...
Page 25: ...25 4 4 MEDIUM XL 3L XL 4 230V 1PH one chamber ...
Page 26: ...26 4 4 MEDIUM XL 3L XL 4 230V 3PH one chamber ...
Page 27: ...27 6 400V 3PH one chamber ...
Page 28: ...28 6 230V 1PH one chamber ...
Page 29: ...29 XL 6 XL 6L XL 9 400V 3PH one chamber ...
Page 30: ...30 XL 6 XL 6L XL 9 230V 1PH one chamber ...
Page 31: ...31 6 XL 6 XL 6L XL 9 230V 3PH one chamber ...
Page 32: ...32 EXPLODED VIEW ...
Page 33: ...33 ...
Page 34: ...34 ...
Page 35: ...35 ...
Page 36: ...36 ...
Page 37: ...37 ...
Page 44: ...44 ...