15
1.8 AMBIENT TEMPERATURE AND AIR CIRCULATION
For air-cooled appliances, the maximum ambient temperature for operation is 32°c. Correct operation cannot
be guaranteed at higher temperatures. The machine may operate safely to a maximum temperature of 38°c.
Remote condensing units must be installed in special rooms or outdoors, protected against direct sunlight by a
shelter or roof structure (at the cost of the purchaser). Sufficient air circulation must be guaranteed at all times.
CONDENSATE DRAINAGE CONNECTION
Fit a condensate/wash water drainage hose as picture.
SHUT DOWN PROCEDURES
In the event of emergency, remove the plug from the power socket.
1.9 OPERATING TIPS
Before starting up the appliance, clean the inside of the cell thoroughly.
PRE-COOLING
Before using the appliance for the first time, or after a prolonged period of disuse, pre-cool the cell by running
an empty cycle until the set operating temperature has been reached. To ensure optimal performance without
any alteration to food quality:
Arrange food products in such a way as to favor the circulation of cold air throughout the cell;
Open the door as little as possible.