background image

 
  

                                     ComCo Systems Inc. |   800.533.3794   |   www.comcosystems.com    

500628 Rev A     

    

     28

 

921 

Series

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Appendix A 

Summary of Contents for 921 Series

Page 1: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 921 Series Installation and Operator Manual ...

Page 2: ... copyright No part of this publication may be reproduced in any form or used as the basis for the sale or manufacture of apparatus without prior written consent by ComCo Systems 2013 ComCo Systems INC All rights reserved Some of the materials and applications described in this publication may be protected under one or more of the following US patents DES272076 4180354 4971481 4984939 5584613 60395...

Page 3: ...4 Operations Specification Customer Unit pg 8 Operations Specification Blower pg 11 Operations Specification Carriers pg 13 Operations Specification Theory of Operation pg 14 Installation Maintenance pg 16 System Setup and Installation Field Wiring Diagram Replacement Parts Help Desk Information pg 29 Return Materials Authorization Procedure Contact Information Contents ...

Page 4: ... is located near the teller unit The Model 921 is configured with three major subsystems 1 Teller Unit TU P N 200430 1 2 Blower Unit P N 200281 3 3 Customer Unit CU P N 201280 Features Teller Unit TU TU 921 200430 1 Manual operated door unit which is suspended from the ceiling typically over countertop Customer Unit CU CU 921 201280 Open carrier access design with optional 2 way video unit Dual Pa...

Page 5: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 4 921 Series Teller Unit Model TU 921 200430 1 ...

Page 6: ... cycle for the system to function properly The teller unit door should only be opened when a carrier is being inserted to send to the customer unit or immediately after a carrier has arrived from the customer unit Opening the door will cancel operation To resume operation close door and press RECALL or SEND Please note the reference guide in Fig 1 0 NOTE Door Close Light next to the manual door ha...

Page 7: ...owers Power ON all lights will be present Power OFF complete system power down If installed it will power down the Customer Video Module CVM SEND Sends a carrier to the customer unit The teller unit door must be closed in order to send a carrier to the customer unit RECALL Recalls a carrier from the customer unit The teller unit door must be closed in order to recall a carrier from the customer un...

Page 8: ...ries Teller Unit P N 200430 1 Dimensional Electrical Specifications Item Measurements Value Teller Unit TU 921 200430 1 Nominal Voltage Current max 24 VAC From Blower 1 Amp OPEN SEND RECALL CLOSE System Controller P N 200155K See Appendix A For System Settings Specification ...

Page 9: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 8 921 Series Customer Unit Model CU 921 201280 ...

Page 10: ... Rev A 921 Series Customer Unit P N 201280 Machine Switch Operating Instructions SEND Sends carrier to Teller Unit CALL Generates audible tone at the Pharmacy Teller Center when depressed Bottom Switch Keypad P N 200574 2 Top Switch Keypad P N 200573 2 Operation ...

Page 11: ...0 921 Series Customer Unit P N 201280 Dimensional Electrical Specifications Item Measurements Value Customer Video Module CVM 2000 200903 10 Nominal Voltage Current max 12 VDC 3 5 Amps 1520 Lane Station 600651 Nominal Voltage Current max 12 VDC 1 5 Amps Specification ...

Page 12: ...11 ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 921 Series Dual Pack Blower Model 200281 3 ...

Page 13: ...ine Power must be done in compliance with the NEC National Electrical Code by authorized qualified personnel 2 115 VAC 0 5 A Resettable Fuse 2 115 VAC 1 5 A Resettable Fuse Class 2 Field Wiring SHOCK HAZARD Disconnect AC Power before Servicing Unit AC Service Disconnect for Unit is located at the Main Junction Breaker Box Use minimum hardware to mount unit in place For mounting location see cut sh...

Page 14: ...transmission tubing or possibly lose their contents during transmission If coins are to be sent it is recommended that they be rolled and placed in a pouch or bag Loads that can shift during transmission may cause malfunction or damage to the carrier or system Carriers are not to exceed a gross weight of 5lbs The contents of the carrier must be fully within the carrier and not caught between edges...

Page 15: ...wer indicator extinguishes 3 CVM Systems only Camera and monitor in CVM are powered off 4 System is now off The power switch may be used to recover from unusual system conditions simply by switching it off and on this will reset the system Send cycle 1 Technician Teller inserts carrier into teller unit 2 Teller closes teller unit door and presses SEND 3 Send cycle begins 4 Pressure blower activate...

Page 16: ...n the Teller Unit Check Valve opens sending vacuum to the Customer Unit 6 Carrier is pulled from Customer Unit into transmission tubing towards Teller Unit 7 Carrier passes Teller Check Valve 8 Carrier is decelerated by pressure ahead of carrier valve in Teller Check Valve blocks pressure from Teller Unit 9 Carrier arrives at Teller Unit 10 Cycle timer times out 11 Recall cycle ends system is now ...

Page 17: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 16 921 Series Installation Cut Sheets NOTE Installation ...

Page 18: ...17 ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 921 Series Installation Cut Sheets NOTE Installation ...

Page 19: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 18 921 Series Installation Cut Sheets NOTE Installation ...

Page 20: ...19 ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 921 Series Installation Cut Sheets NOTE Installation ...

Page 21: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 20 921 Series Installation Field Wiring Diagram D N 500618 NOTE Deceleration switches MUST be wired in Parallel Installation ...

Page 22: ...21 ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 921 Series Installation Field Wiring Diagram D N 500624 NOTE Deceleration switches MUST be wired in Parallel Installation ...

Page 23: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 22 921 Series Installation Field Wiring Diagram D N 500619 NOTE Deceleration switches MUST be wired in Parallel Installation ...

Page 24: ...omCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 921 Series Installation Control Audio Field Wiring Diagram D N 500073 NOTE Refer to Audio Authority Manual for Audio Installation Installation ...

Page 25: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 24 921 Series System Riser Diagram Options Parts Descriptions Installation ...

Page 26: ...rriers Timer Adjustment Adjust timer T1 for approximately 5 seconds greater than the time required for an empty carrier to be recalled from the customer unit to the teller unit this should be 2 3 seconds after the carrier lands at the teller unit See Appendix A for switch settings and other timing settings Maintenance Carriers Carriers should be inspected regularly for signs of wear Carriers landi...

Page 27: ...art Number Usage per Lane Keypad 200923 1 2 Keypad Interface Cable 200967 2 Power Switch Assembly 200391 1 2 Interface Board 200354 2 Control Board 200155K 1 Control Interface Harness 200559 1 Left Hand Door Handle Assembly 201140 1 Right Hand Door Handle Assembly 201140 1 1 Brass Keeper 400178 1 Left Hand Door Assembly 200027 1 1 Right Hand Door Assembly 200027 2 1 Membrane Valve for Receiver Box...

Page 28: ... Interface Harness 200880 1 Blowers Description Part Number Usage per Lane Blower Motor 601003 4 Blower Motor Assembly 200785 4 Blower Interface Board 200717 2 Dual Blower Interface Harness 200748 1 Solid State Relay 609819 4 Transformer Assembly 201170 2 5 Amp Circuit Breaker 604414 2 1 5 Amp Circuit Breaker 604435 2 10 Amp Circuit Breaker 604412 4 Solenoid Assembly 200282 2 Carriers Description ...

Page 29: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500628 Rev A 28 921 Series Appendix A ...

Page 30: ...horization number RMA Please give the Customer Service Representative the following information Company Name and Phone Number Company Contact Store Component s being returned for repair Description of problem Part Serial Number Send your return items to the following address ComCo Systems 306 W Overly Dr Lake Dallas TX 75065 RMA XXXX All RMAs will be processed in the order they are received ComCo ...

Page 31: ...ice Technical Support service comcosystems com 800 533 3794 Option 1 support comcosystems com Parts Orders parts comcosystems com 800 533 3794 Option 2 Equipment and System Sales sales comcosystems com 800 533 3794 Option 3 Project Management 800 533 3794 Option 4 Accounting accounting comcosystems com 800 533 3794 Option 5 https www facebook com ComcoSystems https twitter com comcosystems ...

Reviews: