www.comcoinc.com

TANK ORIFICE
MB1409‐x

BYPASS TUBE
MB2265‐x

TANK ASSEMBLY
MB2200‐10 (Standard)
MB2200‐20 (Tall)

Bypass Tube Chart

TANK ORIFICE

MB1409‐

Standard Tank        

‐1C         ‐1B         ‐1A

Tall Tank      

‐2C         ‐2B         ‐2A

‐18

‐25

‐30

1 = Lean Mixture (less abrasive)
5 = Rich Mixture (more abrasive)

Tank Orifice and Bypass Tube

We have configured the AccuFlo® for your 
particular application. 

Start with these settings.

You have the option to adjust settings. Minor 
changes in powder concentration should be made 
with the Abrasive Blend Control on the front panel.

For more significant changes, the abrasive 
concentration in the air stream can be made 

leaner

(less abrasive) or 

richer

(more abrasive) by 

changing the tank orifice and the bypass tube. 
Contact a Comco Tech Support Specialist for 
information on additional options.

Change the tank orifice using a ¼" nut driver.

Unscrew the bypass tube and lift it out of the 
sleeve. Using the chart below, select the tube 
you desire and insert it in the sleeve. 

Finger tighten only; do not force.

BYPASS TUBE

MB2265‐

1

2

3

2

3

4

3

4

5

Summary of Contents for AccuFlo AF10-CE

Page 1: ...Comco Inc 2151 N Lincoln St Burbank CA 91504 USA Tech comcoinc com 1 818 841 5500 ...

Page 2: ...k Shipping Weight 30 lb 13 6 kg 30 lb 13 6 kg Height 10 5 in 26 7 cm 15 0 in 38 1 cm Width 17 5 in 44 5 cm 17 5 in 44 5 cm Depth 10 0 in 25 4 cm 10 0 in 25 4 cm Air Pressure 10 125 psi 0 7 8 6 bar 10 125 psi 0 7 8 6 bar Powder Capacity 1 liter 2 liters Nozzle Sizes Round 015 060 in ø 38 mm 1 5 mm Other shapes and sizes available Facility Requirements Inlet Air Pressure 70 145 psi 4 8 10 bar Air Vo...

Page 3: ...e traveling out to the nozzle The strength of these modulated pulse and the diameter of the orifice determines the amount of abrasive that drops into the mixing chamber Three mechanisms enable you to change the amount of abrasive in the air stream the tank orifice abrasive blend and bypass tube Tank Orifice A larger orifice increases abrasive flow In most cases the orifice should be at least 5 tim...

Page 4: ...CH INLET AIR FITTING THE ABRASIVE HOSE FROM THE POWDERGATE VALVE RUNS DIRECTLY TO THE NOZZLE DO NOT ROUTE THIS HOSE THROUGH THE VENT PINCH 1 Place the ComfortGrip handpiece inside the work chamber 2 Place the open end of the vent hose into the back of the workstation or into the dust collector hose 3 Connect the power cord and the blast control cable 4 Connect the air supply to the Air In fitting ...

Page 5: ...will cause the blaster to blast When Pin 2 is left floating the blaster will not blast 200mA of current is typical PE Pin 4 provides an optional bonding path to Primary Earth through the AccuFlo If the host is otherwise bonded to PE do not use this pin Regulator Control The regulator must be powered by 24vdc through Pin 7 and ground through Pin 6 The regulator requires 60mA of current The blast pr...

Page 6: ...ust settings Minor changes in powder concentration should be made with the Abrasive Blend Control on the front panel For more significant changes the abrasive concentration in the air stream can be made leaner less abrasive or richer more abrasive by changing the tank orifice and the bypass tube Contact a Comco Tech Support Specialist for information on additional options Change the tank orifice u...

Page 7: ...er 250 000 cycles Unscrew the Output Fitting with a wrench With pliers gently pull the worn Nose from shaft Press on new Nose Install the new Output Fitting Connect the tubing with the blue Quicknut PowderGate Valve Tech Support 1 818 841 5500 7 tech comcoinc com ...

Page 8: ...AF10 CE Components 1 818 841 5500 8 www comcoinc com ...

Page 9: ... the number of blast hours i e actual time the modulator has operated To replace the AccuFlo AF10 CE modulator Disconnect 3 colored tubes from the modulator and the electrical plug from front panel Remove the two screws holding the modulator to the bracket using a Phillips screwdriver Install new the modulator in reverse order making sure the two grommets remain in the bracket AccuFlo AF10 CE Modu...

Page 10: ... sound when the blast is activated If not the modulator may need to be replaced For further details contact Technical Support If nothing happens when the blast is activated Is the nozzle plugged Remove and inspect Is the PowderGate valve failing to open Contact Technical Support If you suspect the PowderGate valve is not closing completely When the PowderGate valve closes place a finger over the e...

Page 11: ...Tech Support 1 818 841 5500 11 tech comcoinc com AF10 CE Electrical Schematic Rev 12 7 21 ...

Page 12: ...AF10 CE Pneumatic Schematic 1 818 841 5500 12 www comcoinc com ...

Page 13: ...ot limited to nozzles powders and attachments not manufactured or supplied by Comco The warranty also does not cover problems resulting from improper or inadequate facilities contaminated air improper power or items that should be expected to wear in normal operation such as nozzles abrasives tubing or fittings This is Comco s only warranty and is in lieu of all other warranties of merchantability...

Page 14: ...Replacing Nozzle Hi Performance AccuFlo Nozzle Options MB2520 18 018 Dia MB2520 30 030 Dia MB2520 46 046 Dia MB2520 60 060 Dia The life of your nozzle will depend on the type of abrasive and air pressure you use Check the nozzle for wear on a regular basis 8 32 Set Screw MB1483 3 Quicknut Hi Performance nozzle 375 Recommended 8 32 tapped hole to Ø 1885 hole set screw Abrasive hose Ø 1885 0005 000 ...