19
f
Configure the call to an entire apartment or to an individual device within the apartment, by completing the following fields:
Description
Enter the description.
ViP address
Enter the ViP address
Master/Slave
From the pull-down menu, choose whether to configure a call to the entire apartment or only to the
master monitor or to a slave monitor, as required.
Emergency call
From the pull-down menu, choose whether to
enable or disable
a priority emergency call (on the
App the contact will be identified by a red cross)
N.B. only 1 emergency contact can be set
f
Configure the call to a switchboard by completing the following fields:
Description
Enter the description
ViP address
Enter the ViP address
Emergency call
From the pull-down menu, choose whether to
enable or disable
a priority emergency call (on the
App the contact will be identified by a red cross)
N.B. only 1 emergency contact can be set
f
Configure the self-ignition of a camera by completing the following fields:
Description
Enter the description
ViP address
Enter the ViP address
Camera
Select the desired camera from the pull-down menu.
f
Configure the activation of an actuator (Generic actuator, Shutter, Door, Lighting..) by completing the following fields:
Description
Enter the description
ViP address
Enter the ViP address
Expansion index
Select the "actuator module" or expansion you wish to to control from the pull-down menu (from 1 to
10)
Output index
From the pull-down menu, select the number of the relay (1 or 2) or the expansion number (from 1 to
10) that you wish to control
f
Configure the activation of the lock-release relay by completing the following fields:
Description
Enter the description
ViP address
Enter the ViP address
Output index
Select the number of the output you wish to to control from the pull-down menu (from 1 to 3)
f
Configure the activation of the relay of an external unit completing the following fields:
Description
Enter the description
ViP address
Enter the ViP address
Intercoms
Switchboards
Cameras
Actuators
Lock-release
External Units
f
Configure the
Lock-release button
, by completing the following fields:
Type
Select from the pull-down menu:
disabled:
to disable the button
peer:
to control the relay of the external unit in communication
fixed-addr:
to control a specific relay
ViP address
Enter the ViP address
Output index
Select the number of the output you wish to to control from the pull-down menu (from 1 to 3)
Lock-release Actions