F) Door Forced-Open Alarm --
Installer Programming
I) Pacifier Tones (Keypress Acknowledgement Tones) --
Installer Programming
J) Allowable Time to Start Door Propped-up Alarm --
Installer Programming
K) Exit Programming Mode
G) Output Activation Announcer --
Installer Programming
H) User Code Entry Mode (Auto or Manual) --
Installer Programming
Locations
8 0
8 0
Locations
8 3
8 3
Locations
9
9
Locations
8 1
8 1
Locations
8 2
8 2
Validation
#
#
Validation
#
#
Validation
#
#
Validation
*
Validation
#
#
Validation
#
#
Code of Functions
1
0
Code of Functions
1
0
Code of Functions
0
1 to 999
Code of Functions
1
0
Code of Functions
1
0
Comments
Door Forced-Open Alarm is Enabled
Door Forced-Open Alarm is Disabled
Comments
Pacifier tones available on keypress
All pacifier tones areoff. Good for place requires silent environment
Comments
No propped-up alarm
Allowable time from 1 to 999 seconds for door left open before the door
propped-up alarm starts
Comments
Keypad exits programming modeand returns to normal operation
Comments
1 second notifying beep is given to notify the person outside to open the door
when output relay is activated with an user code or egress button. Good for the
locking device that gives no sound when it activates, such as a magnetic lock.
Notifying beep disabled and replaced by 2 short successful code entry beeps for
valid user codes
Comments
Auto Entry Mode is selected.
#
key that follows theuser codeis NOTrequired in
code entry. The User Codes MUST be set in the same digit length as the Master
Codein Auto Entry Modeand thecodelength can be4-8 digits.
Manual Entry Mode is selected.
#
key that follows the user code is required in
code entry. The user codes can be 4-8 digits and they are not required to be in
thesamelength as theMaster Code.
In Single User Mode, no matter the selection is Auto or Manual mode, the Master Code and the User Code MUST be set in
thelength of 4 digits.
NOTE:
6
15
APPLICATION EXAMPLES
1) BASIC WIRINGS OF A STAND ALONE DOOR LOCK
NOTE:
Connect the 1N4004 as close as possible to the lock in parallel with the lock power terminals to absorb the back
EMFto prevent it from damaging the keypad. The 1N4004 is not required if the electric lock is ACoperated.
To avoid Electro-Static-Discharge from interfering with the operation of the keypad, always ground the (-) terminal
of the keypad to earth.
Always connect DOOR SENSOR terminal to (-) ground if not used.