EN
22
5
When programming is complete,
Set
S2
DIP switches 1-2-3-4 to the combination 1111 (
PROG
setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
Restore the user code setting on S1.
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8
4.2.3.3 HOW TO PROGRAM THE
PAGING FUNCTION
Example: key = general paging to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set
S2
DIP switch 5-6 to the combination 01
» the Privacy LED flashes
ON
1 2 3 4 6 7
5
8
2
1. Choose the function:
S2
DIP switches
combination in which the paging function (
PAG
) is listed for the keys you wish to program.
2. Addressing:
for internal paging
set S1 DIP switches with the same user code of the internal unit.
for general paging to another user code
set S1 DIP switches with the desired address in
Example: 0100
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
ON
1 2 3 4 6 7
5
8
5
When programming is complete,
Set
S2
DIP switches 1-2-3-4 to the combination 1111 (
PROG
setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
Restore the user code setting on S1.
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8
4.2.3.4 HOW TO PROGRAM THE
SELF ACTIVATION FUNCTION
Example: key
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set
S2
DIP switch 5-6 to the combination 01
» the Privacy LED flashes
ON
1 2 3 4 6 7
5
8
2
1. Choose the function:
and select a
S2
DIP switches
combination in which the self activation function (
AI
) is listed for the keys you wish to program.
2. Addressing:
for self activation function
don't set S1 DIP switches
Example: 0110
ON
1 2 3 4 6 7
5
8
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
ON
1 2 3 4 6 7
5
8
5
When programming is complete,
Set
S2
DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
Restore the user code setting on S1.
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8