EN
27
4.8.2 Operation
√
Monitor on
By pressing the programmed button, it is possible to toggle between the different cameras, according to the following diagram:
External unit
3rd Camera
2nd Camera
1st Camera
4.8.2.1 PROGRAMMING THE NUMBER OF CAMERAS CONNECTED
Select the number of cameras connected using switches 7 and 8 of selector S1, as shown in the following table.
DIP 7
DIP 8
0 Cameras
0
0
ON
1 2 3 4 6 7
5
8
1 Camera
1
0
ON
1 2 3 4 6 7
5
8
2 Cameras
0
1
ON
1 2 3 4 6 7
5
8
3 Cameras
1
1
ON
1 2 3 4 6 7
5
8
4.8.2.2 FUNCTION 1: GENERIC ACTUATOR MODE
√
NOTE: Before programming the module, see the table
“4.8.2.4 Compatibility Table” on page 28
By pressing the button programmed as "generic actuator", it is possible to toggle between the different cameras
Microswitch “
S1
” must be set as shown in following table
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
DIP 6
Setting for generic actuator
1
1
0
0
0
0
ON
1 2 3 4 6 7
5
8
4.8 CCTV CAMERA INTERFACE ART. 1409
Art. 1409 allows to manage analog CCTV camera (up to 3).
4.8.1 Parts description
1.
Terminal block
M2
for system connection:
INA
camera module external control contact
GND
Common contact
V1 S1
Coax input camera 1
V2 S2
Coax input camera 2
V3 S3
Coax input camera 3
2. TM2
Controls frequency of video signal modulation (factory-
set to optimum setting:
do not adjust
)
3. TM1
Controls amplitude of modulated video signal (factory-
set to optimum setting:
do not adjust
)
4.
Programming micro-switches
S1
5.
Terminal block
M1
for system connection:
L OUT L OUT
Bus line output
L IN L IN
Bus line input
~- ~+
Power input 12Vac 20Vdc
1409
1.
2.
3.
4.
5.