14
Other functions: button programming
Programming range
1.
2.
3.
4.
Min. address
S1
Set a code.
S2
x4
OK prog:
x4
KO prog:
S2
Max. address
Cancellation
S1
S2
1.
Enable
2 sec
x10
x10
OK prog:
KO prog:
Disable
2 sec
Take note of the S2, S1 settings and restore on completion of programming
1.
To enter programming mode, set S2 DIP-switch 6 to ON.
» the LED
flashes
S2
2.
Refer to the table
to identify a DIP-switch combination in which the desired functions corresponding
to the buttons you want to program appear, then set the S2 DIP-switches.
Example: For button 4= Self Activation (AI) and button 5 = Call to Secondary Switchboard (CCS), set S2 DIP-switches 1-2-
3-4 as specified in row M in the "Basic configuration" table.
3.
Press and release the buttons involved in the change.
» Correct procedure indication
: the LED
flashes for a few seconds and a confirmation tone sounds.
4.
Exit programming mode by setting S2 DIP-switch 6 to OFF.
» LED
switches off
S2
5.
Set S2 DIP-switches 1-2-3-4 to ON.
When the procedure is complete, restore the initial DIP-switch combination.