background image

 
 

 

 

 

IE-COM-C4141-13

 

 

 

 

 

General 

 

Power: 

Battery 9V or ac/dc adapter 12 V with NiMH accumulator 9V 

_____________________________________________________________________________________________________________________________________________________________ 

If instrument is supplied from external ac/dc adapter, internal 9V battery should be replaced with rechargeable 

NiMH  accumulator.  In  usual  operation  from  adapter  accumulator  is  charged  only  with  small  current. 

If accumulator is totally discharged, its full charging in instrument takes approximately 100 hours. Instrument 

with accumulator is not recommended for permanent operation without ac/dc adapter plugged. Accumulator 
works only as a standby source in case of power mains failure. 

 

Average current consumption: 

0.3 to 1.3 mA (depending on operation mode) 

_____________________________________________________________________________________________________________________________________________________________

 

Battery  life  depends  on  selected  display  refresh  mode  (see  below).  In  FAST  mode  display  is  refreshed  in 

shortest possible interval with highest current consumption. In dynamic mode display is refreshed in interval 

up to 5 s in case measured values remain stable. Refresh interval is shortened to approximately 0.7 s only 
if measured values change. Current consumption in this mode in usual operation is lower, battery life is up to 

4 times longer. The FAST mode is recommend to use only in cases, when slower display response is not 

acceptable. 

Battery voltage drop below 7 V is indicated with blinking of "BAT" in default display mode (displaying of actual 

values) and FAST mode is automatically cancelled to save the battery. At the same time audio indication of 

alarms is automatically switched OFF. 

 

Measuring interval and display reading refresh approximately: 

0.7 s  

in FAST mode 

0.7 to 5 s 

in dynamic mode 

 

Interval of refresh of pressure tendency display: 

0.5 h 

 

Display: 

Backlit two-line LCD 

______________________________________________________________________________________________________________________________________________________________

 

Backlighting turns off automatically 10 seconds after the last keystroke  

  

Protection: 

IP20 

 

Electromagnetic compatibility: 

Device conforms in accordance with EN 61326-1 these norms: 

 

Radiation: 

EN 55022 

class B  

Immunity: 

EN 61000-4-2 

(levels 4/8 kV, class A) 

 

 

 

EN 61000-4-3 

(intensity of electromagnetic field 3 V/m, class B) 

 

 

 

EN 61000-4-4 

(levels 1/0.5 kV, class A) 

 

 

 

EN 61000-4-6 

(intensity of electromagnetic field 3 V/m, class B) 

 

 

 

EN 61000-4-11  (class A) 

 

 

 

EN 61000-4-5 

(class A) 

 

Summary of Contents for Commeter C4141

Page 1: ...www cometsystem com Instruction manual Commeter C4141 Digital thermo hygro barometer with external probe...

Page 2: ...PERATION OF THE DEVICE 8 Switching ON and OFF the device 8 Displaying of actual measured values 8 Function HOLD storing of actual measured values and minimum a maximum memory 9 Functions and settings...

Page 3: ...emperature is measured by RTD sensor Ni1000 6180ppm Instrument is equipped with an external temperature relative humidity probe Instrument compares all measured values except pressure tendency with tw...

Page 4: ...tep 20 C Relative humidity Measuring range 0 to 100 RH Resolution 0 1 RH Accuracy 2 5 RH from 5 to 95 RH at 23 C Response time t90 1 min with plastic sensor cover without filter t90 1 min with plastic...

Page 5: ...5 s in case measured values remain stable Refresh interval is shortened to approximately 0 7 s only if measured values change Current consumption in this mode in usual operation is lower battery life...

Page 6: ...on device 0 to 100 RH probe Temperature and rel humidity restriction The measuring range of the external probe is limited accordance with the graph and must not be exceeded Storage temperature range 1...

Page 7: ...IE COM C4141 13 7 Dimensions...

Page 8: ...t the probe to avoid storing of improper values to the min max memory Displaying of actual measured values In this mode is instrument any time after switching ON It is possible to enter this mode from...

Page 9: ...ermanently updates minimum and maximum memory of each measured values Press MIN key resp MAX key in the default mode to display minimum resp maximum reading These minimum and maximum readings are indi...

Page 10: ...This value illustrates battery condition This selection by pressing ENTER key enables to enter mode of pressure correction to the sea level see below Display refresh mode is indicated In the FAST mode...

Page 11: ...nd setting It is possible to set lower and upper limit for each measured quantity Breaking of the limit is indicated by blinking of the appropriate value on the display If a new alarm was indicated i...

Page 12: ...hen you are offered to set alarm of other input value here relative humidity The procedure is the same as the above temperature limit setting Alarm activation of each value can be disabled by setting...

Page 13: ...replace battery with instrument switched OFF otherwise setting of d REF and AUDI from menu selections and data in memory HOLD MIN and MAX will be lost For the same reason do not disconnect the batter...

Page 14: ...14 IE COM C4141 13 Technical support and service Technical support and service is provided by distributor Contact is included in warranty certificate...

Reviews: