Transport, packing and storage
25
5.8. Storing the unit
These storage conditions apply to the following cases:
To new units.
To units that are already in operation and were prepared for a temporary placing out of
operation, see "Temporary placing out of operation".
Store the units under the following conditions:
Indoors.
Dry.
Dust-free.
Low vibration.
Protected against direct sunlight.
Protected against any aggressive medium.
Storage temperature and relative humidity: see "Technical specifications".
In the case of storing the units for longer than 3 months, the general condition of all
parts and the packing have to be checked regularly.
The packaging has only to be removed just before installation takes place.
Protection caps for the coolant inlet and coolant outlet connections have only to be
removed just before installation takes place.
In order to store the units for more than 6 months, please consult COMET.
5.9. Preparing the unit for the further transport
DANGER
DANGER
Electrical danger!
Work on electrical installations may be carried out by trained and authorized electri-
cians only.
Switch off the unit before starting your work.
Disconnect the unit from mains by pulling the mains plug.
Secure the unit against being switched on again.
Verify that the unit is dead.
Carry out earthing and short circuiting.
Keep unauthorized persons away from the working area.
NOTE
Risk of damage due to improper transportation!
A coolant that has not been drained or a packaging with inappropriate dimensions may cause dam-
age during transport.
Drain the coolant before transporting the unit, see "Draining the coolant".
Use proper packaging.