8
3.6.
Connection of communication options
The UPS has three communication ports:
USB
RS-232
Slot SNMP/AS-400
To enable automatic management and monitoring of the UPS, connect the USB cable supplied with
the device, on one side to the USB socket on the UPS and on the other side to the USB socket on the
computer.
The software provided with the UPS allows you to automate the processes of switching on and off the
receivers connected to the UPS depending on the events that occur on the UPS (e.g. power failure,
low battery level). The software also allows for ongoing monitoring and logging of UPS event history.
RS232 and USB ports cannot be used simultaneously.
The UPS also has an INTELLIGENT SLOT for additional cards, allowing for the use of communication
options. Additionally, you can connect to the device:
•
LAN card - allowing communication via LAN / WAN with the use of e.g. protocols: WWW, SNMP,
Modbus TCP,
•
AS-400 relay contact card for communication with external supervision systems, e.g. BMS, alarm
control units,
•
Modbus card with RS485 port, allowing communication using the Modbus RTU protocol, e.g. with
BMS systems.