COVER MY SERIES – User Manual
COMEX S.A.
4
2.3.
Location
2.3.1.
UPS room
The UPS is intended for indoor installation. The device should be placed in a clean environment
with adequate ventilation to keep the ambient temperature within the required specification
range. The UPS provides forced convection cooling through internal fans. Cold air enters the
device through the vents at the front of the housing and is blown out through the grills at the
rear of the housing. Do not block the ventilation openings.
Depending on the room conditions, the ventilation openings of the power supply should be
regularly cleaned, e.g. with a vacuum cleaner. The accessibility of ventilation will ensure
efficient cooling and extend the life of the device.
Note: The UPS should be installed on a stable and non-flammable surface.
2.3.2.
Battery room
The battery temperature should be stable as it is the main parameter influencing the battery
life and capacity. The optimal operating temperature of the battery is 15-25 ° C. It is
recommended to maintain a nominal temperature of 20 ° C.
Working at higher temperatures shortens the battery life, and working at lower temperatures
reduces their capacity. Each increase of the battery operating temperature by another 8 ° C
reduces the service life by 50%.
Keep batteries away from heat sources and hot air vents.
When installing the battery outside the UPS, use the battery circuit protection located as close
to the battery as possible. Keep the cables connecting the battery and the UPS as short as
possible.
2.3.3.
Storage
If the device is not installed and needs to be stored, it should be protected against excessive
moisture and high temperature. Batteries should be stored in a dry and cool room. The most
suitable storage temperature for the battery is 20-25 ° C. If the appliance is not installed
immediately after delivery, it should be stored indoors so that it is protected from excessive
moisture and heat sources.
2.4.
Unpacking, checking and setting
Before unpacking, carefully inspect the delivered packaging of the device to make sure that it
has not been damaged during transport. After removing it from the packaging, check that the
equipment has no signs of damage. If there is any damage, report it to the supplier immediately.
2.4.1.
Unpacking
The power supply is delivered in a cardboard box on a wooden pallet. To unpack, remove the
cardboard packaging and protective foams inside the packaging. The following shows the device
after removing the packaging.