MAINTENANCE
CLEANING METAL SELF-SUPPORTING GREASE FILTERS
The filters must be cleaned every 2 months of operation, or
more frequently for particularly heavy usage, and can be
washed in a dishwasher.
Pull the comfort panels to open them.
Remove the filters one by one pushing them towards the back
side of the hood unit and simultaneously pulling downwards.
Any kind of bending of the filters has to be avoided when washing
them. Before fitting them again into the hood make sure that they
are completely dry. (The color of the filter surface may change
throughout the time but this has no influence to the filter efficiency).
When fitting the filters into the hood pay attention that they are
mounted in correct position the handle facing outwards.
REPLACING THE ACTIVATED CHARCOAL FILTER
Sept1: Remove the metal grease filters.
If you choose Recirculation Ductless Installation, Activated Charcoal Filters are required for
operation. Please visit Amazon.com and search for Model #
CVP/CVG-CF
to purchase the 2 Pack
of Charcoal Filters. These filters are not washable and must be replaced every 4 months of
operation, or more frequently with heavy usage.
BAFFLE FILTER
10
ACTIVATED CHARCOAL FILTER (RECIRCULATION DUCTLESS INSTALLATION)
Sept2: Locate the motor inside of the range
hood unit, underneath the baffle filters.
Step3: Take the recirculating filter and twist and
lock it into place on the right side of the motor
Close
Step4: Repeat step 3 on the left side of the motor
Step5: Reinstall the arc-flow baffle filters back into
place.