INSTALLATION 

WALL DRILLING AND BRACKET FIXING 

A vertical line up to the ceiling or up to the upper limit, at the center of the area in which the

hood is to be fitted.

A horizontal line 

C

 at a 

X  

A horizontal line 

B

 at

A horizontal line 

A

 at a 

B

.

to the vertical reference line.

Repeat this operation on the other side and on the vertical reference line , checking that

the three marks are leveled.

to the vertical reference line.

Repeat this operation on the other side , checking that the two marks are leveled.

Mark a point (1) on the horizontal line 

B

,

Mark a point (2) on the horizontal line 

C

,

Mark a point (3) on the horizontal line 

A

to the vertical reference line.

Repeat this operation on the other side , checking that the two marks are leveled.

above the cooker top.

inch above the horizontal line

C

B

(1)

A  (3)

Vertical reference line

X

7.48"

below the horizontal line

1.57

"

6.69

"

36.61

"

 

-

 

40.55

"

7.48

"

B

3.15''

1.57

"

3.15

"

3.15

"

6.69

"

unit

inch

36.61" - 40.55"

1.57''

6.69''

Chimney

X

/

15.75"+11.81''

15.35''-

24.41''

15.75

"

Fix the brackets :

 

3/8''

 drill bit.

Drill holes at the marked points with a

Insert the Wall Plugs 11 into the holes.

Fix the hood fixing bracket 

20

 with 3 screws 

10

 (

0.2'' 

x

 1.97''

) at the horizontal line 

B

.

Fix a Chimney fixing bracket 

21

 with 2 screws 

10

 (

0.2'' x 1.97''

)  at the horizontal line 

C

.

7

Summary of Contents for CVP30W4AST

Page 1: ...Hz Free 3 months extension of the original limited warranty period Simply text a picture of your proof of purchase to 1 844 224 1614 The warranty extension is for the three months immediately following the completion of the product s original warranty period MODEL NUMBER CVP30W4AST CVP36W4AST ...

Page 2: ......

Page 3: ...e units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambeing food i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan filters or in exhaust ducts d Use proper pa...

Page 4: ... Upper Decorative Chimney 3 2 2 3 Qty Documentation 1 Instruction Manual 10 11 7 20 Screws M5 x 1 97 Hood fixing bracket 7 Wall Plugs 12 21 6 Screws M4 2 x 0 37 1 1 Chimney fixing bracket Ref Qty Optional Installation Components 2 2 2 1 3 20 12 11 21 10 The Activated Charcoal filter optional Grease filter 30 Grease filter 36 4 1 4 2 ...

Page 5: ...A A MVG30W7AST MVG36W7AST 30 9 0 10 55 36 18 58 10 55 6 73 25 6 29 53 3 ...

Page 6: ...utside the hood can be used in the non vented recirculating version fitting a charcoal filter and the deflector not included you can decide whether to use according to your installation environment Fumes and vapors are recycled through the top grille Non Vented Recirculating Wall Venting Roof Venting A A B B B A A Deflector B 6 round vent A Wall cap B 6 round vent A Roof cap B 6 round vent Local b...

Page 7: ...hould be taped and sealed with 2 metal foil tape The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the Most Efficient and Quiet Operation Use no more than three 90 elbows Make sure there is a minimum of 24 of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together Use clamps to seal all joints in t...

Page 8: ...ll 3 Tape template in place aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall NOTE Ensure that horizontal lines are level prior to marking hole locations Overlap the holes when install the adjustable decorative chimney Mark the hole location with in 0 375 to 0 5 of the ceiling or the upper most hole location Centerline of cabin...

Page 9: ...ontal line B Mark a point 2 on the horizontal line C Mark a point 3 on the horizontal line A to the vertical reference line Repeat this operation on the other side checking that the two marks are leveled above the cooker top inch above the horizontal line C B 1 A 3 Vertical reference line X 7 48 below the horizontal line 1 57 6 69 36 61 40 55 7 48 B 3 15 1 57 3 15 3 15 6 69 unit inch 36 61 40 55 1...

Page 10: ...ng bracket 20 Level the hood and insert 2 long screws 10 into bracket 21 at level B Insert 2 long screws 10 into the hood at level A Install Duct and Insert Plug Install 6 duct over the flange on the fan body Use 2 wide metal tape to make an air tight seal between the duct and the fan body Install a clamp to secure the ductwork securely Remove Carbon Filters if installed Insert the plug into a pro...

Page 11: ...viously marked on level D Slide the upper decorative chimney 2 2 up to the horizontal line D Insert 2 small sheet metal screws into the sides of the bracket to secure the Upper Decorative Chimney 21 D Install Carbon Filters 12 B Non Vented Recirculation Installation Fix the upper chimney onto the bracket 21 with 2 screws 12 0 17 x 0 37 supplied with the hood 9 ...

Page 12: ...nd press again to turn them off ON OFF MOTOR SWITCH Press on this switch to turn on off the motor SPEED SWITCH Press on this switch the motor runs at LOW speed SPEED SWITCH Press on this switch the motor runs at MEDIUM speed SPEED SWITCH Press on this switch the motor runs at HIGH speed 10 ...

Page 13: ...LEANING METAL SELF SUPPORTING GREASE FILTERS The filters must be cleaned frequently and can be washed in a dishwasher or a hot detergent solution Depress the latch to remove the filters Avoid bending the filters when washing and allow the filters to completely dry before reinstalling The color of the filter surface may change throughout the time but this has no influence to the filter efficiency W...

Page 14: ... filter Disconnect the terminal of LED light Press LED light on the back of the front plate take the LED light out Replace the lamp Press LED light on the front of front plate install the LED light on the front plate Connect the terminal of LED light and light leads Reinstall the grease filter Reinstalling the LED Light Module Max Power Voltage Picture Service Number Round Diameter 2 76 1 5W DC 12...

Page 15: ...e Every implied warranty including any statutory warranty or condition of merchantability or fitness for particular purpose is disclaimed except to the extent prohibited by law in which case such warranty or condition is limited to the duration of this written warranty This warranty gives you specific legal rights You may have other legal rights that vary d epending on where you live Some states or ...

Page 16: ...P N 16173000A19609 ...