Service Manual -
DVC 09/12/18/24 SF Series
26
31
7.4.1
4
Point check function
Press the LED DISPLAY or LED or MUTE button of the remote controller three times, and then
press the AIR DIRECTION or SWING button three times in ten seconds, the buzzer will
sound
for
two seconds. The air conditioner will enter into the information
i
nquiry status. You can press the
LED
DISPLAY or AIR DIRECTION button to check the next or front item’s information.
When the AC enter
s
the “information
i
nquiry” status, it will display the code name
in 2 seconds,
the details are as follows.
Enquiry information
Displaying code
Meaning
T1
T1
Indoor room temp.
T2
T2
Indoor coil mid temp.
T3
T3
Outdoor coil temp.
T4
T4
Outdoor temp.
T2B
Tb
Indoor coil outlet temp.
TP
TP
Compressor discharge
temp.
TH
TH
IPM modular temp.
Targeted Frequency
FT
Targeted Frequency
Actual Frequency
F
r
Actual Frequency
Indoor fan speed
IF
Indoor fan speed
Outdoor fan speed
OF
Outdoor fan speed
EXV opening angle
LA
EXV opening angle
Compressor continuous running time
CT
Compressor continuous
running time
Causes of compressor stop.
ST
Causes of compressor
stop.
Reserve
A0
Reserve
A1
Reserve
0
Reserve
1
Reserve
2
Reserve
3
Reserve
4
Reserve
5
Reserve
6
Reserve
L
Reserve
A
Reserve
U
Reserve
T
When the AC enter into the information enquiry status, it will display the code value in the next 25s
,
the details are as follows.
Summary of Contents for A-DVC09SF-0
Page 8: ...Service Manual DVC 09 12 18 24 SF Series 8 6 For B DVC09SF 0 For B DVC12SF 0 For B DVC18SF 1 ...
Page 9: ...Service Manual DVC 09 12 18 24 SF Series 9 7 For B DVC24SF 1 ...
Page 13: ...Service Manual DVC 09 12 18 24 SF Series 13 For A DVC24SF 1 ...
Page 14: ...Service Manual DVC 09 12 18 24 SF Series 14 4 Refrigerant Cycle Diagram ...
Page 42: ...Service Manual DVC 09 12 18 24 SF Series 42 47 P W N U ...
Page 43: ...Service Manual DVC 09 12 18 24 SF Series 43 48 N V N W ...
Page 55: ...Service Manual DVC 09 12 18 24 SF Series 55 This page intentionally left blank ...