508183-01
Issue 2114
Page 2 of 52
Technical Speci ications -
GUH96T
REV CODE
REVISION
NOM. CFM X 100
2 TON ADD ON COOLING
3 TON ADD ON COOLING
4 TON ADD ON COOLING
5 TON ADD ON COOLING
CABINET WIDTH
A = 14.5” WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5” WIDTH
BTUH INPUT
HEATING INPUT X 1000
GAS
G = GAS FURNACE
CONFIGURATION
UH = UPFLOW/HORIZONTAL
AFUE
80 = 80% EFFICENCY
92 = 92% EFFICENCY
95 = 95% EFFICENCY
96 = 96% EFFICENCY
G UH 96 T
G UH 96 T 00 44 55 BB 33 M
M
STAGES/MOTOR
A =SINGLE STAGE PSC
C =SINGLE STAGE CONSTANT TORQUE
T = TWO STAGE VARIABLE SPEED ECM
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
1st Stage
2nd Stage
AFUE
(ICS)
Nominal*
Cooling
Capacity
(tons)
Gas
Inlet
(in.)
Volts/
Hertz/
Phase
Min.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Input
(Btuh)
Output *
(Btuh)
Input
(Btuh)
Output *
(Btuh)
UPFL
OW / HORIZONT
AL
GUH96T045B3M
29,000 28,000 44,000 42,000
96.0
3
1/2
120-60-1
15
7.7
40
130
GUH96T070B3M
43,000 41,000 66,000 62,000
96.0
3
1/2
120-60-1
15
7.7
40
138
GUH96T090C3M
57,000 55,000 88,000 84,000
96.0
3
1/2
120-60-1
15
7.7
40
154
GUH96T090C5M
57,000 55,000 88,000 85,000
96.0
5
1/2
120-60-1
20
12.8
40
166
GUH96T110C5M
72,000 70,000 110,000 105,000 96.0
4
1/2
120-60-1
15
12.8
40
173
GUH96T135D5M
88,000 84,000 132,000 126,000 96.0
5
1/2
120-60-1
20
12.8
40
188
Note: For vent length and clearances to combustibles, please reference installation instructions.
* At full capacity