507715-01
Page 21 of 61
Issue 1716
Table 6A.
GUH95A Maximum Allowable Intake or Exhaust Vent Length in Feet
Standard Termination at Elevation 0 - 4,500 ft
Number of
90° Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
045
070
090
110
135
045
070
090
110
135
045
070
090
110
135
1
76
61
39
19
n/a
110
95
63
38
n/a
132
132
113
113
109
2
71
56
34
14
105
90
58
33
127
127
108
108
104
3
66
51
29
9
100
85
53
28
122
122
103
103
99
4
61
46
24
n/a
95
80
48
23
117
117
98
98
94
5
56
41
19
90
75
43
18
112
112
93
93
89
6
51
36
14
85
70
38
13
107
107
88
88
84
7
46
31
9
80
65
33
8
102
102
83
83
79
8
41
26
n/a
75
60
28
n/a
97
97
78
78
74
9
36
21
70
55
23
92
92
73
73
69
10
31
16
65
50
18
87
87
68
68
64
Standard Termination Elevation 4,501 - 10,000 ft
Number of
90° Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
045
070
090
110
135
045
070
090
110
135
045
070
090
110
135
1
76
61
39
n/a
n/a
110
95
63
38
n/a
132
132
113
113
109
2
71
56
34
105
90
58
33
127
127
108
108
104
3
66
51
29
100
85
53
28
122
122
103
103
99
4
61
46
24
95
80
48
23
117
117
98
98
94
5
56
41
19
90
75
43
18
112
112
93
93
89
6
51
36
14
85
70
38
13
107
107
88
88
84
7
46
31
9
80
65
33
8
102
102
83
83
79
8
41
26
n/a
75
60
28
n/a
97
97
78
78
74
9
36
21
70
55
23
92
92
73
73
69
10
31
16
65
50
18
87
87
68
68
64
*Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.