507715-01
Page 23 of 61
Issue 1716
Table 6C.
GUH95A Maximum Allowable Exhaust Vent Length with Furnace Installed in a Closet or Basement Using
Ventilated Attic or Crawl Space for Intake in Feet
Standard Termination at Elevation 0 - 4,500 ft
Number of
90° Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
045
070
090
110
135
045
070
090
110
135
045
070
090
110
135
1
66
51
29
9
n/a
95
95
73
38
n/a
113
112
93
93
89
2
61
46
24
4
90
90
68
33
108
107
88
88
84
3
56
41
19
n/a
85
85
63
28
103
102
83
83
79
4
51
36
14
80
80
58
23
98
97
78
78
74
5
46
31
9
75
75
53
18
93
92
73
73
69
6
41
26
4
70
70
48
13
88
87
68
68
64
7
36
21
n/a
65
65
43
8
83
82
63
63
59
8
31
16
60
60
38
3
78
77
58
58
54
9
26
11
55
55
33
n/a
73
72
53
53
49
10
21
6
50
50
28
68
67
48
48
44
Standard Termination Elevation 4,501 - 10,000 ft
Number of
90° Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Capacity
Capacity
Capacity
045
070
090
110
135
045
070
090
110
135
045
070
090
110
135
1
66
51
29
n/a
n/a
95
95
73
38
n/a
113
112
93
93
89
2
61
46
24
90
90
68
33
108
107
88
88
84
3
56
41
19
85
85
63
28
103
102
83
83
79
4
51
36
14
80
80
58
23
98
97
78
78
74
5
46
31
9
75
75
53
18
93
92
73
73
69
6
41
26
4
70
70
48
13
88
87
68
68
64
7
36
21
n/a
65
65
43
8
83
82
63
63
59
8
31
16
60
60
38
3
78
77
58
58
54
9
26
11
55
55
33
n/a
73
72
53
53
49
10
21
6
50
50
28
68
67
48
48
44
NOTE
: Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length
calculation.