This stove should NOT be used as the
only
source of heat in the home. Power outages and periodic
maintenance will result in a total loss of heat.
Contact local building or fire officials regarding restrictions and installation inspection requirements for
your area.
Contact your local authority (Municipal building department, Fire department, Fire prevention bureau,
etc...) to determine the need for a permit.
Keep combustible materials (such as grass, leaves, etc...) at least 3 feet away from the flue outlet on the
outside of the building.
Installation and repair of this pellet stove should be done by a qualified service person. The appliance
should be inspected before use, and at least annually by a qualified service person. It is imperative that
the control compartments, fire box, and circulating air passageways of the stove be kept clean.
CAUTION!
During a power outage, the stove will shut down safely. Do not open the main door or ash pan door.
During a power failure, the exhaust fan will not run. Keeping the doors sealed will allow the exhaust
vent to draft out naturally. When the power is restored, the stove will not restart. If the exhaust
temperature is still 126° F (52° C) when power is restored, the exhaust and convection fans will
continue to run until the stove cools.
Over Fire Protection
: If the stove is being over fired or burning too hot, the high limit switches will
automatically shut down the stove to avoid damage to other components. If the temperature on the
hopper reaches 197° F (92° C), the auger will automatically stop and the stove will shut down. The
exhaust fan will continue to run until the proof of fire switch cools. Allow the stove to cool before
attempting to re-ignite.
NOTICE!
Install at least one smoke detector on each floor of your home to ensure your safety. They
should be located away from the stove, and close to the sleeping areas.
You should have separate CO monitors for areas near the stove
4
CAUTION!
If the electrical power fails at any time when the stove is hot, keep all stove doors closed.
This will limit the amount of smoke in the space.
Never shut the stove down (while running) by unplugging it from the power source.
Never shut the stove down (while running) by switching off the main power switch on the
rear of the stove.
WARNING!
This stove has a manufacturer set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this stove in a manner inconsistent with the