ComfortFlame.US.com
900555-00 NC
10
FLOOR CLEARANCES
A. If installing appliance on the floor level, you must maintain the
minimum distance of 14" to combustibles
(see
Figure 8
).
B. If combustible materials are less than 14" to the fireplace, you
must install appliance at least 5" above the combustible flooring
(see
Figure 9
).
INSTALLATION
Continued
14"
Min.
Combustible
Material
Noncombustible
Material
Hearth
5"
Min.
Combustible
Material
Figure 9 - Minimum Fireplace Clearances Above
Combustible Flooring
Figure 8 - Minimum Fireplace Clearances if Installed at
Floor Level
CAUTION: Do not remove the data plates attached
to the heater base assembly. The data plates contain
important warranty and safety information.
WARNING: You must secure this heater to fire-
place floor. If not, heater will move when you adjust
controls. Moving heater may cause a gas leak or
log misplacement.
CAUTION: Do not pick up heater base assembly
by the burner. This could damage heater. Only handle
base assembly by grates.
IMPORTANT
:
Make sure the heater burners are level. If heater is
not level, heater will not work properly. For thermostat models,
avoid damage to thermostat bulb. Avoid nicks or sharp bends in
thermostat bulb wire. Keep thermostat bulb in mounting bracket
until ready to mount base to floor. See
Optional Positioning Of
Thermostat Sensing Bulb
,
page 22
.
WARNING: If installing in a sunken fireplace,
special care is needed. You must raise the fireplace
floor to allow access to heater control panel. This will
ensure adequate air flow and guard against sooting
and controls being damaged. Raise fireplace floor
with noncombustible material. Make sure material
is secure.
INSTALLING HEATER BASE ASSEMBLY