CLEARANCE TO COMBUSTIBLES

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60Hz circuit with a properly

grounded outlet is required.  Preferably, the

heater will be on a dedicated circuit.  Other 

appliances on the same circuit may cause the 

circuit breaker to trip or the fuse to blow when the

heater is in operation.  The unit comes standard

with a 6' (1828mm) long three wire cord exiting

from the rear of the fireplace.  Plan the installation

to avoid the use of an extension cord.  If an

extension cord must be used, it must be a mini-

mum 16 AWG three wire with grounding type plug

connector and rated no less than 1875 Watts.

ELECTRICAL SPECIFICATIONS

3

LEG ASSEMBLY

Before using your unit, please install the legs as shown in diagram below.

Back...................0"/0mm

Sides..................0"/0mm

Floor...................0"/0mm

Top.....................24"/610mm

Front..................36”/915mm

WARNING:  Electrical 

outlet wiring must comply with

local building codes and all

other applicable 

regulations to reduce the risk

of fire, electrical shock and

injury.

WARNING:  Do not use this

fireplace if any part of it has

been under water.  Immediately

call a qualified service 

technician to inspect the 

fireplace and replace any part

of the electrical system if 

necessary.

Voltage................120 VAC/60Hz

Total Amps...........11.3 Amps

Total Watts...........1500 Watts

Heater Ratings.....1400 Watts

(+5%,-10%)

Summary of Contents for ES4011

Page 1: ...00 642 2112 West Chester OH 45069 Made in China 1112 If you have any questions regarding this product call 1 800 642 2112 and ask for our product specialists Mon Fri 9 00 5 00 EST or e mail productspe...

Page 2: ...ric shock fire hazard and will void the warranty Installation instructions 2 General 2 Locating Your Electric Fireplace 2 Heater Assembly 3 Clearance To Combustibles 3 Electrical Connections 3 Electri...

Page 3: ...lly grounded in accordance with local codes with the current CSA C22 1 Canadian local codes for USA installations Follow local codes and National Electrical Code ANSI NFPA NO 70 and Canadian Code CZ 2...

Page 4: ...WG three wire with grounding type plug connector and rated no less than 1875 Watts ELECTRICAL SPECIFICATIONS 3 LEG ASSEMBLY Before using your unit please install the legs as shown in diagram below Bac...

Page 5: ...s are in the 1 position When the heater reaches the desired temperature the heater and HEATER TURBO indicator light will turn off and the fan will stop working for air flow FLAME INTENSITY Turn the di...

Page 6: ...product be operated with missing or broken glass 2 Do not strike or slam the glass 3 Do not use abrasive cleaners to clean the glass 4 Replacement glass is available from the manufacturer and replace...

Page 7: ...ing this heater be sure to unplug heater from wall outlet Do not only turn off heater from the main ON OFF switch be sure to unplug this heater SPECIFICATIONS Model ES4011 Voltage 120V 60Hz Total Amps...

Reviews: