background image

REPLACING LIGHT BULBS

CAUTION:  Even though the glass is safety glass it

may break if bumped, struck or dropped.  Care

must be taken when handling the glass.

T

here is one (1) 40W Type B-10 bulb for the

flame generation.

1.  Unplug the unit.

2.  Open the door of the unit with the handle.

3.  Loosen the two (2) screws at the front of the

logset inside the stove.

4.  Carefully lift the

logset up far enough

to access the light

bulb.  You will find one

40W Type B-10 bulb

under the logset bed.

5.  Loosen and remove the burnt out bulb and

replace with new 40 watt Type B-10 bulb.

6. Return the logset bed and secure with the two

screws.

7.  Plug in the unit.

MAINTENANCE OF MOTORS

The motors used on both blower fan and

flame simulator assembly are prelubricated

for the extended warranty of the motor, no

further lubrication is required.  However, 

periodic cleaning/vacuuming of the fan/heater

unit is recommended.

GLASS INFORMATION

1.  Under no circumstances should this 

product be operated with missing or broken

glass.

2.  Do not strike or slam the glass.

3.  Do not use abrasive cleaners to clean the

glass.

4.  Replacement glass is available from the

manufacturer and replacement should be 

carried out by a qualified service person.

CLEANING

To clean the unit, first turn off controls on unit

and unplug unit from power source.

To clean the glass door:  remove dust with

clean dry cloth or to remove finger prints and

other marks clean glass with clean damp

cloth.  Do not use abrasive cleaners or spray

liquids on glass door surfaces.

Metal and metal painted parts should be

cleaned with clean damp cloth only.  Do not

use abrasive cleaners or spray liquids on this

surface.

5

WARNING:  Make sure

that the power is turned

off before proceeding.

WARNING:  Wait until the

unit has completely

cooled before attempting

any cleaning.

SERVICE INSTRUCTIONS

WARNING:  Disconnect power

before attempting any 

maintenance or cleaning to

reduce the risk of fire, electri-

cal shock or personal injury.

WARNING:  Do not exceed

 40  Watts for light bulb.

Use of a higher rated bulb

may result in a fire 

causing property damage

and personal injury.

Summary of Contents for ES4011

Page 1: ...00 642 2112 West Chester OH 45069 Made in China 1112 If you have any questions regarding this product call 1 800 642 2112 and ask for our product specialists Mon Fri 9 00 5 00 EST or e mail productspe...

Page 2: ...ric shock fire hazard and will void the warranty Installation instructions 2 General 2 Locating Your Electric Fireplace 2 Heater Assembly 3 Clearance To Combustibles 3 Electrical Connections 3 Electri...

Page 3: ...lly grounded in accordance with local codes with the current CSA C22 1 Canadian local codes for USA installations Follow local codes and National Electrical Code ANSI NFPA NO 70 and Canadian Code CZ 2...

Page 4: ...WG three wire with grounding type plug connector and rated no less than 1875 Watts ELECTRICAL SPECIFICATIONS 3 LEG ASSEMBLY Before using your unit please install the legs as shown in diagram below Bac...

Page 5: ...s are in the 1 position When the heater reaches the desired temperature the heater and HEATER TURBO indicator light will turn off and the fan will stop working for air flow FLAME INTENSITY Turn the di...

Page 6: ...product be operated with missing or broken glass 2 Do not strike or slam the glass 3 Do not use abrasive cleaners to clean the glass 4 Replacement glass is available from the manufacturer and replace...

Page 7: ...ing this heater be sure to unplug heater from wall outlet Do not only turn off heater from the main ON OFF switch be sure to unplug this heater SPECIFICATIONS Model ES4011 Voltage 120V 60Hz Total Amps...