background image

 

- 8 -  

Version: May 2011 

 
 
SPA ASSEMBLY 

*

Please note if fitting your spa with 

colored skin you must first inflate spa 

50% and then place skin over wall edge.

 

 

1. Take all parts out of box. Compare 
package contents with contents 
diagram found on previous page. 
 
2. Unfold spa vessel (4), inflation 
connection cover (7), and inflatable 
inner cover (5). 
 
3. Remove label(s) from liner-to-
power pack union nut. 
 
4. Attach the three (3) feet to the 
bottom of the power pack. 
 
5. Connect the inflation hose to the 
blower exhaust fitting on the top of 
the power pack. 
 

 

 

The key lock pin must be inserted 
into the adapter of the inflation 
hose fitting when inflating. Failure 
to insert the key lock pin may 
result in injury. 
 
 

6. Plug the power pack into the 
electric outlet. Press the Turbo Wave 
On/Off button to start the inflation. 
 

 

Note: The power pack will make a 
rattling noise while the pump is 
running with no water. This is 
normal. Do not run the power 
pack without water for more than 
15 minutes.  

 
 
 
 
 
 
 

 

7. Using adapter shown, inflate spa 
vessel (4). 
 

 

 

 

Note:  Please note power 
pack will inflate vessel 
approximately 80% full. Shut 
off air blower and finish 
inflating with hand pump 
provided using pressure 
gauge. * Inflate to yellow zone 
on pressure gauge. 

 

8. Using power pack and inflation 
hose, fill inflatable inner cover and 
connection cover until firm.  * Do not 
over inflate! 
 
9. Place white foam pad under spa 
vessel. 

 
 

 
 
 

 
 
 
 
 
 
 
 

Meijer.com

Summary of Contents for AiriSpa DS1oval110v

Page 1: ...wner s Manual Models DS1oval110v DSRND110V Oval AiriSpa Round AiriSpa Manufactured by Comfort Line Products Inc 2717 N Tamiami Trail N Fort Myers FL 33903 US 888 891 5585 Canada 877 633 8827 www comfo...

Page 2: ...SIBLE DROWNING WARNING TO AVOID INJURY EXERCISE CARE WHEN ENTERING OR EXITING THE SPA OR HOT TUB WARNING PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A PHYSICIAN BEFORE USING A SPA OR HOT TUB WA...

Page 3: ...al enclosures or electrical equipment metal water pipe or conduit within 5 feet 1 5m of the unit as needed to comply with local requirements 4 DANGER Risk of Injury a Replace damaged cord immediately...

Page 4: ...40 C 104 F are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes B Since excessive water temperatures have a high pot...

Page 5: ...use pump failure and void warranty 4 Maintain proper water PH 7 4 7 6 is ideal Failure to do so may cause damage to vinyl liner pump seals heater element and damage will not be covered by warranty 5 I...

Page 6: ...a as required to comply with the National Electric Code or local requirements INDOOR INSTALLATION Give special consideration to the following issues when installing your spa indoors 1 Make sure the fl...

Page 7: ...in height will provide a sufficient area for installation 3 Verify that there is adequate room to place the spa and permit safe access 4 Check local code requirements for restrictions fencing enclosur...

Page 8: ...the inflation hose fitting when inflating Failure to insert the key lock pin may result in injury 6 Plug the power pack into the electric outlet Press the Turbo Wave On Off button to start the inflati...

Page 9: ...liner starting from the center of liner and proceeding outwards towards the wall Be careful not to over fill the spa or the spa may overflow during use Each average adult will raise the water level in...

Page 10: ...the water pump will be air bound and no water will flow This will prevent the spa from heating and the water will not be filtered Make sure water is flowing from the return nozzle before continuing 6...

Page 11: ...ault to 100 F when electric power is restored Turbo Operation To turn the turbo wave pump on or off push the on off button Look to see if the spa blows bubbles uniformly all the way around the spa The...

Page 12: ...ir The vinyl can be repaired using standard vinyl repair techniques Pieces of material can be obtained through your dealer Vinyl Repair If your liner does get a tear or puncture your dealer can provid...

Page 13: ...g the power pack before draining the spa The spa is easily drained by using a hose to siphon out the water Do not lift the spa if it contains more than 1 4 inch of water 2 Remove and clean your filter...

Page 14: ...rom a high pressure garden hose 6 Place the filter back in the filter housing Make sure the filter is properly seated in the housing and that the o ring is properly seated in the o ring groove Note En...

Page 15: ...not function properly do not use your spa Call the dealer or factory immediately for instructions Do not bypass the GFCI device 1 Turn on the turbo wave blower 2 Push the test button on the GFCI locat...

Page 16: ...orking properly 4 Turbo wave pump makes a squealing noise Do not continue running the turbo wave pump Contact the manufacturer for instructions No Heat 1 Dirty filter Clean the filter per the instruct...

Page 17: ...ge and the spa will resume normal operations Should this problem occur repeatedly please call our customer support for further instructions Leaks 1 The two small connections between the power pack and...

Page 18: ...e 120 VAC 60 Hz 12 Amps 240 VAC 50 Hz 6 Amps 1000 Watt heater Weight Dry Spa approx 77lbs With water approx 1700 lbs MODEL DSRND110v AiriSpa Capacity Seating 4 5 adults Water 250 gallons Height 28 inc...

Page 19: ...y Obligations of Purchaser The purchaser must establish by dated sales slip invoice or installation receipt the date of original purchase In order to supply the customer with the most up to date servi...

Page 20: ...ect to change without notice Obtaining Warranty Service Please review the purchase and online self help resources offered at www comfortlineproducts com before seeking warranty services Our knowledge...

Reviews: