background image

LED only blinks red

i

Testing Airflow

Install the CR2450 Coin Cell Battery included in the kit. 

Step 6. Power the WLDC Damper Control

The WLDC Damper Control can be mounted on any wall about 
5’ off the ground (typical thermostat height) using the hardware 
kit included. 

Step 5. Mount the WLDC Wall Control

Using Multiple Dampers to Define a Zone

If needed, up to 4 dampers can be connected together to 
define the space.

IN

OUT

IN

IN

OUT

IN

IN

OUT

IN

IN

OUT

IN

To DDC2 
Damper 
Control

Also, make sure the ID # on the WLDC is matching the ID # 
on the DDC2. The ID numbers can be found on the ID 
labels on the circuit boards.

LED does not blink

i

Troubleshooting

Step 3. Install Modulating Damper

Install a modulating damper in the trunk line supplying air to 
the space. Up to four dampers can be connected to define a 
zone.

Plug one end of the Plug&Play cable into the “IN” connector 
on the damper actuator and the other end into the Zone 1 
connector on the DDC2 Damper Control. 

1)

2)

Turn on power to the HVAC equipment. Observe a green LED on 
the DDC2 circuit board and a green LED on the damper actuator.

Step 4. Apply Power

At the thermostat, activate a heating or cooling call. Set airflow 
to 100%. Measure or feel the airflow going to the space as a 
reference. Now rotate the knob on the WLDC fully counter 
clockwise to 0% to reduce airflow. Within about 15 seconds  the 
LED on the WLDC will blink green after a successful 
communication. You should measure or feel very little airflow. 
Now rotate the knob clockwise to 50%. Measure or feel the 
airflow going to the space. You should feel more airflow but not 
as much as at 100%. If not, see troubleshooting. If the LED does 
not blink green, see Troubleshooting.

Make sure the battery is installed correctly. Also an indicator 
of low battery. 

Make sure the DDC2 Damper Control is powered - green 
LED on. Also make sure the WLDC and DDC2 are within 
range - about 100’ within the home. To see the LED on the 
DDC2, you may need to remove the cover. 

Press and hold in the areas 
indicated near the top of the 
control to release the cover. 

Insert the CR2450 Lithium 
Coin Cell battery. Make sure 
+ side is facing up.

Replace cover by lining up the plastic tabs on the wall base to 
the grooves on the bottom of the cover then snap into place.

Limited 5-Year Warranty

The 5-year warranty is limited to the repair or replacement of 
defective product due to parts failure or defective workmanship.

26072 Merit Circle #110 / Laguna Hills, CA 92653
949-916-0945 Fax 949-458-8502 www.eControlsUSA.com

eControls

100% 

Airflow Setting

LED

Green

0%

Red

Between 

100% and 0%

No LED

Damper LEDs and Position

Damper Position

Open

Closed

Partially Closed