TROUBLE SHOOTING
If an error message occurs, the thermostat will display one of the following errors;
E0 : Internal failure. The thermostat is defective. Thermostat must be replaced.
E1 : Internal room sensor defective or short-circuited. Thermostat must be replaced.
E2 : External floor sensor disconnected, defective or short-circuited. Requires floor sensor reconnection or
replacement.
E5 : Internal overheating. Installation requires inspectIon.
SETTING PARAMETER VALUES – MENU MODE
Parameter settings allows you to set a range of values to define heating options and temperatures.
See the MTD3 included manual to view the full range of parameter options. Most default values need no adjustment.
To enter menu mode;
> Press Menu/Select button for 5 seconds.
> Scroll through menu options with arrow buttons
> Press Menu/Select to enter selection. [See full instruction manual]
> Scroll down to [donE] and press Menu/Select to exit menu mode.
MENU
DESCRIPTION
SETTINGS
DEFAULT
APP
Choose sensor to control heating
A / F / C / AF / AE
F [Floor]
SCA
Set the min. and max. temperatures
0ºC - 40.0ºC
0ºC - 40.0ºC
tP
Temperature read out
Flo / ro
Flo [floor]
LCd
Select; Temp. setting & Display setting
C / F / nu & SP / tP / CL
C [celcius] & SP[setpoint]
AdJ
Calibrate the measured room temperature
nSb
Night setback temperature
2.0ºC - 8.0ºC
5ºC
dEF
Frost protection
5.0ºC - 10.0ºC
8ºC
PWM
Duration of the heating periods
oFF / on / Aut
PLi
Power limit
0 - 30min
0
tiME
Time and ev ent setting
ModE / dAY / Hour / Min
SW
Software v ersion
donE
Sav e settings and
Exit menu