BLOWER PERFORMANCE SPECIFICATIONS

11

*CVM970804CNA

Cooling Speed

(@ .1" - .8" w.c. ESP)

*CVM970804CNA

Heating Speed

(@ .1" - .5" w.c. ESP; Rise Range:  35 - 65°F)

Tap

Adjust

High-Stage

CFM

Low-Stage

CFM

Tap

Adjust

High-Stage

CFM

Rise

(°F)

A

Minus 10%

753

500

A

Minus 10%

1,111

65

Normal

837

556

Normal

1,234

58

Plus 10%

921

612

Plus 10%

1,357

53

B

Minus 10%

920

643

C

Minus 10%

1,193

60

Normal

1,022

714

Normal

1,325

54

Plus 10%

1,124

785

Plus 10%

1,458

49

C

Minus 10%

1,085

754

D

Minus 10%

1,298

55

Normal

1,206

838

Normal

1,442

50

Plus  10%

1,327

922

Plus 10%

1,586

45

D

Minus 10%

1,328

892

D

Minus 10%

1,375

52

Normal

1,475

991

Normal

1,528

47

Plus 10%

1,623

1,090

Plus 10%

1,681

43

*CVM971005CNA

Cooling Speed

(@ .1" - .8" w.c. ESP)

*CVM971005CNA

Heating Speed

(@ .1" - .5" w.c. ESP; Rise Range:  35 - 65°F)

Tap

Adjust

High-Stage

CFM

Low-Stage

CFM

Tap

Adjust

High-Stage

CFM

Rise

(°F)

A

Minus 10%

706

472

A

Minus 10%

1,583

57

Normal

784

524

Normal

1,759

51

Plus 10%

862

576

Plus 10%

1,935

46

B

Minus 10%

970

670

B

Minus 10%

1,617

56

Normal

1,078

744

Normal

1,797

50

Plus 10%

1,186

818

Plus 10%

1,977

45

C

Minus 10%

1,249

834

C

Minus 10%

1,656

54

Normal

1,388

927

Normal

1,840

49

Plus 10%

1,527

1,020

Plus 10%

2,024

44

D

Minus 10%

1,589

1,067

D

Minus 10%

1,693

53

Normal

1,766

1,185

Normal

1,881

48

Plus 10%

1,943

1,304

Plus 10%

2,069

43

Notes

All furnaces ship as high speed for cooling. Installer must adjust blower
speed as needed.

For most jobs, about 400 CFM per ton when cooling is desirable.

CFM between .5" and .8" w.c. is tabulated for cooling purposes only.

Summary of Contents for *CVM970603BNA*

Page 1: ...rty damage or personal injury due to improper service procedures performed by an unqualified person Refer to Service Manual RS6612009 for installation operation and troubleshooting information Refer t...

Page 2: ...n will not be responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any persona...

Page 3: ...alentador de agua por medio de gas etc no deben ser operados en au cerveau et meme la mort Advertencia especial para la instalaci n de calentadores manejadoras de aire en reas cerradas como estacionam...

Page 4: ...MVM97 0603BNA MVM97 0803BNA MVM97 0804CNA MVM97 1005CNA MVM97 1205DNA Heating Data High Fire Input 60 000 80 000 80 000 100 000 120 000 High Fire Output 58 200 77 600 77 600 97 000 116 400 Low Fire S...

Page 5: ...enclosure where accessibility clearances are greater CVM97 0603BNA CVM97 0803BNA CVM97 0804CNA CVM97 1005CNA Heating Data High Fire Input 60 000 80 000 80 000 100 000 High Fire Output 58 200 77 600 77...

Page 6: ...IDE VIEW FRONT VIEW RIGHT SIDE VIEW CONDENSATE DRAI N TRAP EXTERIOR CONNECTIO N RIGHT OR LEFT SIDE PVC VENT FLUE PIPE 2 PVC ALTERNATE VENT FLU E LOCATIO N RIGHT SIDE DRAIN TRAP EXTERIOR HOLES HIGH VOL...

Page 7: ...03BNA 17 28 34 CVM970803BNA 17 28 34 CVM970804CNA 21 28 34 A 34 4 11 14 25 28 C 6 6 11 14 14 25 3 2 2 1 2 23 14 1 1 1 E UNFOLDED FLANGES D FOLDED FLANGES 18 FOLDED FLANGES 20 UNFOLDED FLANGS 2 1 2 6 2...

Page 8: ...0 1 322 54 B Minus 10 725 486 B Minus 10 1 184 n a Normal 806 540 Normal 1 316 55 Plus 10 887 594 Plus 10 1 448 50 C Minus 10 921 635 C Minus 10 1 250 57 Normal 1 023 705 Normal 1 389 52 Plus 10 1 125...

Page 9: ...153 42 MVM971205DNA Cooling Speed 1 8 w c ESP MVM971205DNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 780 492 A Mi...

Page 10: ...CVM970803BNA Cooling Speed 1 8 w c ESP CVM970803BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 562 365 A Minus 10...

Page 11: ...81 43 CVM971005CNA Cooling Speed 1 8 w c ESP CVM971005CNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 706 472 A Min...

Page 12: ...ED IT MUST BEREP LACEDWITH 3 IF ANYOF THEORIGINAL WIREASSUPP LIED WITH THE USEDWHEN SERVICING 2 MAN UFACTURER S SPEC IFIEDREP LACEMENT PAR TS MUS T BE 1 SET HEA T ANTICIPATOR ON ROOM THERMOSTAT AT 0 7...

Reviews: