FURNACE SPECIFICATIONS

4

¹ Natural Gas BTU/h
²
³

Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run

and must be 2" or 3" diameter PVC.

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined

May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

and noise issues.

may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility
clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

*MVM97

0603BNA

*MVM97

0803BNA

*MVM97
0804CNA

*MVM97
1005CNA

*MVM97

1205DNA

Heating Data

Hi gh Fi re Input¹

60,000

80,000

80,000

100,000

120,000

Hi gh Fi re Output¹

58,200

77,600

77,600

97,000

116,400

Low-Fi re Stea dy-Sta te Input¹

30,000

40,000

40,000

50,000

60,000

Low-Fi re Stea dy-Sta te Output¹

29,100

38,800

38,800

48,500

58,200

AFUE²

97

97

97

97

97

Tempera ture Ri s e Ra nge (°F)

20 - 50

30 - 60

25 - 55

35 - 65

35 - 65

Vent Di a meter³

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

No.  of  Burners

3

4

4

5

6

Circulator Blower

Ava i l a bl e AC @ 0.5” ESP

1.5 - 3

1.5 - 3

1.5 - 4

41,675

41,675

Si ze  (D x W)

11" x 8"

11" x 8"

11" x10"

11" x 10"

11" x 11"

Hors epower @ 1075 RPM

1/2

1/2

3/4

1

1

Speed

VS  ECM

VS  ECM

VS  ECM

VS  ECM

VS  ECM

Filter Size (in²)

Perma nent

739

766

862

862

1035

Di s pos a bl e

370

383

431

431

517

Electrical Data

Mi n. Ci rcui t Ampa ci ty

4

8.8

8.8

11.6

15.4

15.4

Max. Overcurrent Devi ce (a mps )

5

15

15

15

20

20

Shipping Weight (lbs)

118

121

142

144

157

Summary of Contents for *CVM970603BNA*

Page 1: ...rty damage or personal injury due to improper service procedures performed by an unqualified person Refer to Service Manual RS6612009 for installation operation and troubleshooting information Refer t...

Page 2: ...n will not be responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any persona...

Page 3: ...alentador de agua por medio de gas etc no deben ser operados en au cerveau et meme la mort Advertencia especial para la instalaci n de calentadores manejadoras de aire en reas cerradas como estacionam...

Page 4: ...MVM97 0603BNA MVM97 0803BNA MVM97 0804CNA MVM97 1005CNA MVM97 1205DNA Heating Data High Fire Input 60 000 80 000 80 000 100 000 120 000 High Fire Output 58 200 77 600 77 600 97 000 116 400 Low Fire S...

Page 5: ...enclosure where accessibility clearances are greater CVM97 0603BNA CVM97 0803BNA CVM97 0804CNA CVM97 1005CNA Heating Data High Fire Input 60 000 80 000 80 000 100 000 High Fire Output 58 200 77 600 77...

Page 6: ...IDE VIEW FRONT VIEW RIGHT SIDE VIEW CONDENSATE DRAI N TRAP EXTERIOR CONNECTIO N RIGHT OR LEFT SIDE PVC VENT FLUE PIPE 2 PVC ALTERNATE VENT FLU E LOCATIO N RIGHT SIDE DRAIN TRAP EXTERIOR HOLES HIGH VOL...

Page 7: ...03BNA 17 28 34 CVM970803BNA 17 28 34 CVM970804CNA 21 28 34 A 34 4 11 14 25 28 C 6 6 11 14 14 25 3 2 2 1 2 23 14 1 1 1 E UNFOLDED FLANGES D FOLDED FLANGES 18 FOLDED FLANGES 20 UNFOLDED FLANGS 2 1 2 6 2...

Page 8: ...0 1 322 54 B Minus 10 725 486 B Minus 10 1 184 n a Normal 806 540 Normal 1 316 55 Plus 10 887 594 Plus 10 1 448 50 C Minus 10 921 635 C Minus 10 1 250 57 Normal 1 023 705 Normal 1 389 52 Plus 10 1 125...

Page 9: ...153 42 MVM971205DNA Cooling Speed 1 8 w c ESP MVM971205DNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 780 492 A Mi...

Page 10: ...CVM970803BNA Cooling Speed 1 8 w c ESP CVM970803BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 562 365 A Minus 10...

Page 11: ...81 43 CVM971005CNA Cooling Speed 1 8 w c ESP CVM971005CNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 706 472 A Min...

Page 12: ...ED IT MUST BEREP LACEDWITH 3 IF ANYOF THEORIGINAL WIREASSUPP LIED WITH THE USEDWHEN SERVICING 2 MAN UFACTURER S SPEC IFIEDREP LACEMENT PAR TS MUS T BE 1 SET HEA T ANTICIPATOR ON ROOM THERMOSTAT AT 0 7...

Reviews: