Specifications 

 

GENERAL SPECIFICATIONS 

DESCRIPTION 

 

 

 

19”/23” rack mount housing via reversible rack ears 

(steel powder coated dark gray housing)

  

 

Copper bus components tin-nickel plated, input bus 
bars configured for two-hole compression lug landing 
up to 300A per bus depending upon configuration 

 

Bullet terminal 1RU circuit breakers available in 3–
100A ratings per breaker position, circuit breaker trip 
detection via monitoring circuit with user 
programming of installed breaker inventory 

 

LED front panel indicators for input power, breaker 
trip alarm 

(available on the 016-131-10 version)

 

 

Removable front panel cover protects circuit breaker 
toggles from nuisance tripping  

 

Front access circuit breakers and controls  

(rear access input and output terminations) 

 

Rear plastic clear cover for termination protection 

PART # 

CONFIGURATION 

DESCRIPTION 

PN 016-131-10 

A/B input, -48VDC, 300A per input: 

 

A/B isolated input, 300A maximum, 

 

8A/8B circuit breaker sockets 

(100A rated per socket)

 

 

19”/23” rack mount 

 

Dark gray color 

 

No supervisory controller  

(LED status indicator only)

 

 

 

 

 

 

 

 

 

About Comm/net Systems 

Comm/net Systems, Inc. (CSI) is the leader in high power density 
communications power systems. Comm/net offers comprehensive 
power and communications site systems integration and 
deployment services via a national footprint of regional branch 
offices. Additional information can be found at 

Corporate Headquarters 

Comm/net Systems, Inc.  
4237

24th Avenue West 

Seattle, WA 98199 

Tel:

 206.282.8670 

Fax:

 206.282.8684 

24/7 Sales & Service 

To purchase Comm/net Systems 
solutions, contact your Comm/net 
Systems representative at:  
(800) 274-0544 or e-mail:  

© 2011 Comm/net Systems, Inc. All rights reserved. Comm/net Systems, and the Comm/net Systems logo are registered trademarks of Comm/net Systems, Inc. 
in the United States and other countries. All other trademarks, service marks, registered marks, or registered service marks are the property of their respective 
owners. Comm/net Systems assumes no responsibility for any inaccuracies in this document. Comm/net Systems reserves the right to change, modify, transfer, 
or otherwise revise this publication without notice. 

DOCUMENT NUMBER 

016-131-30,

 R

03,

 PUBLISHED 

J

ANUARY 

2011

 

 

Summary of Contents for Matrix 016-131-10

Page 1: ...Matrix 1RU High Power Density DC Distribution Center SETUP AND OPERATION MANUAL S E T U P A N D O P E R A T I O N M A N U A L...

Page 2: ...ed at the factory to withstand the normal rigors of shipping However you should carefully inspect the box and contents to confirm that no damage occurred in transit Most shipping carriers require noti...

Page 3: ...rack use the two holes further back on the sides of the panel 2 Install the chassis ground cable A chassis ground cable should be landed on the two studs marked Chassis Ground on the left side of the...

Page 4: ...on corresponding to the output channel to be fed viewing the front of the panel from left to right the positions are A1 A2 A3 A4 A5 A6 A7 A8 then B1 B2 B3 B4 B5 B6 B7 B8 Push until the circuit breaker...

Page 5: ...ory Button The Breaker Inventory Button when held for more than five seconds is used to store the breaker inventory in nonvolatile memory The button may also be used to temporarily silence indefinitel...

Page 6: ...is turned off the red Breaker Trip LED will turn on and the alarm beeper will sound When the breaker is turned back on the LED will turn off and the alarm beeper will silence 4 The breaker inventory...

Page 7: ...successful Panel and Breaker Rating Limitations The panel is rated for a maximum current of 300A per bus The sum of the eight distribution breakers on either side of the panel may not exceed 300A The...

Page 8: ...ine Breakers Each slimline breaker has two threaded brass screw hole features designed for extraction The breaker extraction tool is fitted with screw features designed to attach to the breaker Attach...

Page 9: ...sory controller LED status indicator only About Comm net Systems Comm net Systems Inc CSI is the leader in high power density communications power systems Comm net offers comprehensive power and commu...

Reviews: