SETUP AND OPERATION MANUAL

F O R   T E L E C O M   B R O A D B A N D

v30/30 Distribution Panel

Summary of Contents for v30/30

Page 1: ...SETUP AND OPERATION MANUAL F O R T E L E C O M B R O A D B A N D v30 30 Distribution Panel...

Page 2: ...es via a national footprint of regional branch offices Additional information can be found at www commnetsystems com 2018 Comm net Systems Inc All rights reserved Comm net Systems and the Comm net Sys...

Page 3: ...SETUP AND OPERATION MANUAL F O R T E L E C O M B R O A D B A N D v30 30 Distribution Panel...

Page 4: ...D COULD RESULT IN INJURY OR DEATH DANGER INDICATES A HAZARDOUS SITUATION WHICH IF NOT AVOIDED WILL RESULT IN SERIOUS INJURY OR DEATH Product support If you have any questions concerning Comm net Syste...

Page 5: ...ration 9 5 1 Overview 9 5 1 1 Firmware Features 9 5 1 2 Firmware Icons 10 5 2 Home Screen 11 5 2 1 Bus Load and Voltage Displayed Per Bus 11 5 2 2 Display Per Breaker Status 11 5 2 3 Alarm Indication...

Page 6: ...V30 30 DISTRIBUTION PANEL SETUP AND OPERATION MANUAL PAGE vi THIS PAGE INTENTIONALLY LEFT BLANK...

Page 7: ...er position 4RU distribution panel with 40A connectorized outputs and an advanced touch screen display Breakers are available for this panel in ratings from 2 ampere up to 30 ampere 2 2 Features y y M...

Page 8: ...V30 30 DISTRIBUTION PANEL SETUP AND OPERATION MANUAL PAGE 2 Purpose and Applicability THIS PAGE INTENTIONALLY LEFT BLANK...

Page 9: ...sed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore take care to install the equipment in an environment compatible wit...

Page 10: ...e included 12 24 hardware into the mounting ears see Figure 3 4 3 Chassis Ground CAUTION DO NOT ENERGIZE THE PANEL BEFORE CHASSIS GROUND IS CONNECTED The chassis ground is located in the side of the p...

Page 11: ...ER TO COPPER CONNECTIONS y y SEE APPENDIX C ON PAGE 19 FOR COMPRESSION LUG SPECIFICATIONS TOOLING AND ORDERING INFORMATION Table 3 INPUT TERMINATION SPECIFICATIONS TERMINATION TYPE HOLE STUD SIZE CENT...

Page 12: ...mbedded web server NOTE For initial configuration it is recommended to use a crossover Cat 5 5e 6 UTP cable to connect a laptop directly to the Ethernet port of the v30 30 panel If the laptop is confi...

Page 13: ...default When the panel is ready to be turned on lift up the front panel door and carefully reach into the top section of the panel and flip the switch to the right ON position See Figure 11 Note this...

Page 14: ...V30 30 DISTRIBUTION PANEL SETUP AND OPERATION MANUAL PAGE 8 Installation THIS PAGE INTENTIONALLY LEFT BLANK...

Page 15: ...TTINGS Manual Offset Load per Breaker Set Breaker Ampacity 0 35A Set Breaker Alarm Threshold 40 100 ALARMS Adjustable overload alarm threshold per breaker 40 100 Breaker Overload Breaker Overload Warn...

Page 16: ...rload Breaker Overload Bus Over Voltage Bus Under Voltage Bus Redundancy Breaker Redundancy Module Overload Module Communication Lost Orange MINOR ALARM Bus Overload Warning Breaker Overload Warning B...

Page 17: ...red for inventoried breakers breaker overload or breaker trip 5 2 3 Alarm Indication If an alarm occurs press the alarm icon at the top left of the screen to access the System Alarms screen Table 12 A...

Page 18: ...splayed with a SET button to set breaker ampacity Press this to enter the breaker ampacity keypad screen To enter a new ampacity for the selected breaker 1 Use keypad to enter an ampacity between 1A a...

Page 19: ...1 Input Feeder Size Press the SET button to adjust feeder fuse size for A1 A2 B2 and B1 busses 1 Use keypad to enter a feeder fuse size between 100A and 300A 2 Press SAVE button to save feeder fuse si...

Page 20: ...les and busses are automatically inventoried if data is being received by the controller 5 6 3 Test Modes This screen allows the user to test the major alarm relay and onboard audibble alarm Exiting t...

Page 21: ...68 123 1 y y Primary DNS 192 168 123 1 y y Secondary DNS 8 8 8 8 Once you establish a connection to the embedded Ethernet module use the following credentials to gain access to the protected data and...

Page 22: ...l and SNMP Settings Configure SNMP Settings y y SNMP trap source address y y SNMP trap destination address y y Configure email settings y y Configure SMTP server y y Enter user name email address and...

Page 23: ...ircuits Up to 60 30A 30B Input Voltage 0 42 to 60V DC Input Current 300A max per input 600A max total load Maximum Input Interruption Device 375A Interrupt Rating 750A Maximum Breaker Size 35A Slimlin...

Page 24: ...V30 30 DISTRIBUTION PANEL SETUP AND OPERATION MANUAL PAGE 18 Product Specifications V30 30 DISTRIBUTION PANEL SETUP AND OPERATION MANUAL PAGE 18 Appendix A Mechanical Drawings...

Page 25: ...T W25VT W25RT X25RT 2 O 538 149 10 Standard Barrel Burndy YAV26L2TC38FX Burndy U26RT W26VT W26RT X26RT 2 O 538 099 10 Long Barrel Burndy YAZV262TC38FX Burndy U26RT W26VT W26RT X26RT 4 O 538 133 10 Sta...

Page 26: ...r 745 433 10 Red Black 745 290 10 Blue Black 745 424 10 Red Red Tracer 745 438 10 10 12 Blue Blue Tracer 745 434 10 Red Black 745 421 10 Blue Black 745 425 10 Red Red Tracer 745 298 10 7 Blue Blue Tra...

Page 27: ...Inputs r03 dlb 2018 07 16 2 2 1 A1 A10 BREAKER MODULE 1A A11 A20 BREAKER MODULE 2A A21 A30 BREAKER MODULE 3A B10 B1 BREAKER MODULE 1B B20 B11 BREAKER MODULE 2B B30 B21 BREAKER MODULE 3B 300A Max 300A...

Page 28: ...V30 30 DISTRIBUTION PANEL SETUP AND OPERATION MANUAL PAGE 22 Product Specifications V30 30 DISTRIBUTION PANEL SETUP AND OPERATION MANUAL PAGE 22...

Page 29: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 30: ...hase Comm net Systems solutions contact your Comm net Systems representative at 800 274 0544 or e mail sales commnetsystems com 2018 Comm net Systems Inc All rights reserved Comm net Systems and the C...