background image

PTS Video

Click or Scan

 Select your preferred torque mode (ships in standard torque) Press the device push pad to 

the desired setting. (Recommend to fully depress and release 5%, giving the device room for 

changing door conditions.)

Step 2-

  While depressing the push pad, apply power. (i.e. presenting the credential to the reader).

Step 3-

Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, release 

the pad and now the adjustment is  complete. If not to your liking repeat the 3 steps. 

Step 4-

Once you found the correct location, turn PTS switch to OFF position.

Setting PTS

**Important Info**

Make sure to set PTS before finishing installation

Technical Information

Step 1-

2 Beeps

3 Beeps

5 Beeps

6 Beeps

Beeps

Explanation

Solution

Over Voltage

Under Voltage

Retraction or dogging failure

PUSH TO SET

> 30V unit will shut down. Check voltage & adjust to 24 V.

< 20V unit will shut down. Check voltage & adjust to 24 V. 

After 1st fail: 5 beeps then immediately attempts to retract again.

After 2nd fail: 5 beeps with pause in-between for 30 seconds then device 

attempts to retract again.

After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract.

 

To Reset: Depress bar for 5 seconds at any time.

Device is recording it’s new position and power mode 

after the 6th beep.

Troubleshooting & Diagnostics

4 Beeps Failed Sensor

Verify all 3 sensor wires are installed correctly. Replace sensor if 

problem persists by contacting office.

# 2 0 3 8 7 _ C

U S   c u s t o m e r   s u p p o r t   1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   w w w. c o m m a n d a c c e s s . c o m   |   C A   c u s t o m e r   s u p p o r t   1 - 8 5 5 - 8 2 3 - 3 0 0 2

mm4s switches

on
on

off

STANDARD TORQUE

HIGH TORQUE

PTS PROGRAMMING LOCKED

PTS PROGRAMMING on

off

Average Latch Retraction Current:  2 Amp

Average Holding Current:  250 mA

High Torque Mode

Average Latch Retraction Current: 1 Amp

Average Holding Current:  215 mA

Standard Torque Mode

SPECIFICATIONS

•  Input Voltage:   24VDC +/- 10%

•  Wire gauge:  Minimum 18 gauge

•  Direct wire run - no relays or access control 

units in-between power supply & module

Summary of Contents for FLP-UL-M-KIT

Page 1: ... Punch recommend or 3 16 drill bit 5 16 Nut driver recommended or Flat head screwdriver 2 Phillips head screwdriver D E A B C The Command Access FLP UL M KIT is a field installable motorized latch pullback kit for the Falcon 24 25 series devices 2 0 3 8 7 _ C U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 ...

Page 2: ...ust to 24 V After 1st fail 5 beeps then immediately attempts to retract again After 2nd fail 5 beeps with pause in between for 30 seconds then device attempts to retract again After 3rd fail 5 beeps every 7 minutes device will not attempt to retract To Reset Depress bar for 5 seconds at any time Device is recording it s new position and power mode after the 6th beep Troubleshooting Diagnostics 4 B...

Page 3: ...and Access exit devices field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory For more information click here or go to our website Electrified Exit Device Installation Example 2 0 3 8 7 _ C U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 ...

Page 4: ...slot on the underside of the kit as you grab onto the roll pin 5 Slide housing off device exposing the baserail and pushpad 2 Slightly depressing the push pad and keep the attaching hooks steady grab onto the roll pin 4 Bring the back of the motor down onto the baserail 6 Installation Instructions 2 0 3 8 7 _ C U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s...

Page 5: ...trofit or you can remove the VD connector to hard wire take stripped wire end and push into the push go connector CONTINUED Line up slots in motor mount to drop onto existing tabs in baserail 7 10 11 9 Visually confirm hooks are attached to roll pin If not repeat Step B 8 2 0 3 8 7 _ C U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r...

Page 6: ... Select your preferred torque mode ships in standard torque Press the device push pad to the desired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release t...

Reviews: