Next, plug in the push & go connector into
the MM4S
Set PTS instructions below
CONTINUED
mm4s switches
2
on
on
off
STANDARD TORQUE
HIGH TORQUE
PTS PROGRAMMING LOCKED
PTS PROGRAMMING on
off
1
# 2 0 3 8 7 _ C
U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w. c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2
11.
12.
Setting PTS
Step 1-
Select your preferred torque mode (ships in standard torque) Press the device push pad to the
desired setting. (Recommend to fully depress and release 5%, giving the device room for
changing door conditions.)
Step 2-
While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 3-
Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped,
release the pad and now the adjustment is complete. If not to your liking repeat the three
steps.
Step 4-
Once you found the correct location, flip the dip switches to off to lock programming.