Commander Connect Owners Manual
74
Selecting the Line Group that the Remote Notification calls are to use
The outgoing line group to be used for remote notification calls can be changed.
•
From the Programming station, press the PROGRAM key.
•
Press the Scroll Down key (
) until “System Programming” is displayed.
•
Select “System Programming”.
•
Enter the System Programming Password
•
Select “System”.
•
Scroll down and select “Remote Notification”.
•
Select “Outgoing group”.
•
Select the group.
Notification delay timer
The time interval between receiving a message and making the first remote notification attempt
is programmable. This is set at 15 minutes (900 seconds) in default and can be set between 1
and 30 minutes (60 - 1800 seconds).
•
From the Programming station, press the PROGRAM key.
•
Press the Scroll Down key (
) until “System Programming” is displayed.
•
Select “System Programming”.
•
Enter the System Programming Password and select “System”.
•
Scroll down and select “Timers”.
•
Select “Notification Delay”.
•
Enter the value between 60 and 1800 seconds and press “Confirm”.
Notification interval timer
If a remote notification fails this is the time the system waits before retrying the call. This is set at
5 minutes (900 seconds) in default. The range is 60 - 900 seconds (1-15 minutes).
•
From the Programming station, press the PROGRAM key.
•
Press the Scroll Down key (
) until “System Programming” is displayed.
•
Select “System Programming”.
•
Enter the System Programming Password and select “System”.
•
Select “Timers”.
•
Select “Notification Interval”.
•
Enter the value between 60 and 900 seconds and press “Confirm”.