background image

6

4

.

GUI Description

3..

(stand-by mode) Operation 
- By pressing the Monitor button repeatedly, the monitor will work as following in order.  
Camera 1 

( Camera 2 ) 

OFF 

Camera 1 ............ 

(On talking mode)Operation 
- By pressing Monitor button repeatedly, the monitor will work as following in order.  

Camera1 

( Camera 2 ) 

Camera 1 

( Camera 2 ) ............ 

Monitoring

: function to see the image of visitor in the entrance. 

6

7

3) Delete individual RF cards

Press program number (4) and press OK button (E)

Enter the password and press the OK button (E).

When individual deletion mode is successfully entered, the KEY LED will blink.

Tag the card to be deleted to the RF receiver.

If you tag another card continuously, you can delete multiple cards at once.

Press the Cancel button (C) and the KEY LED stops blinking and individual deletion

is completed.

4) Delete all RF cards

Press program number (5) and press OK button (E)

Enter the password and press the OK button (E).

When all deletion mode is successfully entered, the KEY LED will blink.

Press and hold the OK button (E) for 2 seconds, the whole deletion will proceed

with the beep sound.

When the whole deletion is completed, beep sound and KEY LED will stop..

Summary of Contents for DRC-40DK

Page 1: ...t responsible for any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly The company is not responsible for any safety accidents caused by abnormal operation of the product User Manual DRC 40DK 41DK U...

Page 2: ...Contents 1 Safety Warning Caution 2 1 Overview 4 2 How to use 4 3 Wiring Diagram 10 4 Installation 11 5 Package 11 6 Specification 12 ...

Page 3: ... it may cause an electric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not using it for a long period of time It may shorten the product lifespan or cause a fire Please don t install the product in the place where there is much oil smoke or humidity It may cause an...

Page 4: ...power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the designated connection cable within the maximum calling distance designated for the product It may reduce the product performance Please check the use voltage and current for the DC only products and use ...

Page 5: ...ter RF 1A recommended sold separately If the power supply from the adapter is poor disconnection or malfunction the power supplied from the monitor can be used as an emergency power source Notes when using emergency power 1 The emergency power source is supplied from monitor for 30 seconds when the monitor is called by the camera 2 In this case some functions may cause difference from normal opera...

Page 6: ...tomatic call operates at all time when removed from the wall regardless of power supply status Reset password If you forget your password you can reset it as follows 1 With the monitor enter the door camera monitoring function Try to press door opening button 7 times quickly within 20 seconds 2 Then LED of the camera is blinking and push OK Button E for 3 seconds to reset password 2 2 Set the func...

Page 7: ...n E the key LED stops blinking and the setting is completed 2 RF card registration Up to 1 024 cards can be registered Press program number 3 and press OK button E Enter the password and press the OK button E When the RF card registration mode is successfully entered the KEY LED will blink Tag the card to be registered to the RF receiver If you tag another card continuously you can register all th...

Page 8: ... you can delete multiple cards at once Press the Cancel button C and the KEY LED stops blinking and individual deletion is completed 4 Delete all RF cards Press program number 5 and press OK button E Enter the password and press the OK button E When all deletion mode is successfully entered the KEY LED will blink Press and hold the OK button E for 2 seconds the whole deletion will proceed with the...

Page 9: ...the level number press the OK button E and the key LED stops blinking and the setting is completed When completed beep sound is heard as the number of level Door open by Password After entering the password press the door number you want to open and then press OK button E ex When opening door 1 2580 1 OK button E Door open by RF card After tagging RF card to the RF receiver press the door number y...

Page 10: ...t is fixed in level 1 to maintain Communication quality It cannot be adjust the beep volume during Calling and Communication mode 8 ON OFF Anti theft switch Press program number 8 and press OK button E Enter the password and press the OK button E When anti theft setting mode is successfully entered the KEY LED will blink Anti theft function OFF Enter 0 Anti theft function ON Enter 1 Press the OK b...

Page 11: ... KEY LED will blink LED ON only when the key touched Input 0 LED ON every time with power supplied Input 1 After entering the number press the OK button E and the key LED stops blinking and the setting is completed 3 Wiring Diagram Precautions When wiring the household monitor connect as follows Failure to do the wiring as shown below may cause the video audio noise ...

Page 12: ...n 5 Package Item Description Qty CONN 4Px300 4 wire connector CONN 2Px300 2 wire connector Bracket Bracket for installation Screw GH1T 4x18 Bracket screw Screw PHM 3x8 Bracket Monitor User Manual English version manual ...

Page 13: ...CMOS IMAGE SENSOR 0 52 megapixels Imaging angle 93 horizontal 50 vertical 110 diagonal Adjustable angle 13 pan and tilt RF Module 13 56MHz Operation temp 10 tested up to 40 50 Dimension mm DRC 40DK 127 W x193 H x54 D DRC 41DK 127 W x193 H x63 D Distance 28 meters Φ 0 5 UTP It must be observed Resistance under 10 Ω per 100 meters on UTP Cat 5e Caution We recommend the COMMAX adaptor We are not resp...

Page 14: ...m si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com PM0743KM0010 513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com ...

Reviews: