background image

Thank you for purchasing COMMAX products.

Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow 
instructions to use a product exactly.

The company is not responsible for any safety accidents caused by abnormal operation of the product.

Thank you for purchasing COMMAX products.

Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow 
instructions to use a product exactly.

The company is not responsible for any safety accidents caused by abnormal operation of the product.

Nurse call function JNS-70MN

User Manual

www.safemag.ru

www.safemag.ru

Summary of Contents for JNS-70MN

Page 1: ...any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a pr...

Page 2: ...rching the bed 17 Designating the bed group 19 Deleting the bed 23 Recent calls 24 Bed designation in charge 25 Setting the bed group number 38 2 Configuration Setting the environment 41 Users notice...

Page 3: ...patient 4 Staff call function 5 Emergency situation function 6 Simultaneous situation function 7 Broadcasting function 8 Smart control function 8 1 Searching the bed 8 2 Designating the bed group 8 3...

Page 4: ...4 I Main screen composition Main screen Page movement Room number Bed number Whole broadcasting Group broadcasting Smart control Remote control www safemag ru www safemag ru...

Page 5: ...the relevant room number press the bed number Then you can speak with by calling the relevant patient In case of speaker phone mode you can speak with if you pick the handset Screen using the speed di...

Page 6: ...t room number with the button in front press the asterisk If you press the pound button after entering bed number you can speak with the relevant patient by calling him or her In case of speaker phone...

Page 7: ...r of bed and room requesting call are displayed as green and yellow wall paper is switched Call request screen 2 If you pick the handset or press the speaker phone button the number of bed and room re...

Page 8: ...during the conversation with a patient stand by call list will be shown If you select the stand by list while talking previous call will be ended and conversation with selected bed will be started Sta...

Page 9: ...le registered in the server IP PBX to the nurse s cell phone Once the nurse get the phone a main receiver is displayed the number of bed on a screen In a main receiver outside call should be ended in...

Page 10: ...presses the presence switch from patient s call and visits the bed of the patient in a bed if you try call request on the screen of main receiver in a nurse station the number of bed and emergency so...

Page 11: ...ed in a ward or outside lavatory or shower room 2 If you press the call button once more or pull the emergency switch in the place occurred in the emergency situation emergency will be cancelled and s...

Page 12: ...n case of ward of general lavatory and shower room are marked as same number In case of outside room number represents designated number 9997 and lavatory or shower room are marked differently in bed...

Page 13: ...imultaneous situation notice 1 In case of emergency during conversation or incoming call in the middle of emergency you can check them at the same time Simultaneous situation notice screen Call mark E...

Page 14: ...roadcasting Able to broadcast for whole rooms in connection with receiver 1 Pick the handset or deliver a message after pressing the whole broadcasting in speaker mode Whole broadcasting implementatio...

Page 15: ...handset or press the group broadcasting at the bottom of menu in speaker phone mode 2 With using the dial button in front or selecting the group to broadcast press the group number and deliver a mess...

Page 16: ...is function is provided in order to register and change the bed phone in the main receiver Because ID of first released bed phone is identified each bed phone can be used through remote control www sa...

Page 17: ...r in the blank to enter enter the all numbers of the installed bed inside the ward the most installed beds number inside the ward or the highest bed number inside the ward 2 After selecting the edit b...

Page 18: ...e exploration press the exit button Then in a main screen each bed s hot key shortcut registered automatically can be checked Exploration progress screen ex A certain ward in a general hospital has fr...

Page 19: ...group designation of registered bed Bed group filter Bed selection button Bed ID Room no Bed no Bed group ID Bed group ID selection Bed group change button Bed group deletion button Quit button 1 Thro...

Page 20: ...selecting the beds you want to change press the Bed group ID selection button and select the group number to change Group F is default setting number Bed selection and Bed group ID selection button sc...

Page 21: ...up Number changing screen 3 After selecting Bed ID and group number to change press the change button Then group number of Bed ID is changed Group number change progress screen www safemag ru www safe...

Page 22: ...22 4 If you press the delete button after selecting Bed ID and group number group ID of default state is changed to F www safemag ru www safemag ru...

Page 23: ...eement message of deletion pops up if you press the relevant bed 2 If you press Yes the relevant bed is deleted 3 In case of return to main screen press the Home button of navigation button or Home at...

Page 24: ...between user and patient can be checked It can check the place to send and receive date and time to start a call Talk time Incoming calls Outgoing calls Bed number list Dialing time list Talk time lis...

Page 25: ...the nurse in charge during a nurse s absence in nurse station This setting is possible to set with smart phone or main receiver Currently this can be used the Database must be installed on a IP PBX s...

Page 26: ...en the name and phone number of the selected nurse are shown in a blank to enter at the top After editing the contents by selecting the blank to enter press the edit button Then the contents will be m...

Page 27: ...le name box Delete button Start time setting button E After entering a name in a blank to enter of profile name enter the star time by pressing the start time setting button After entering the end tim...

Page 28: ...ted name is shown in the edit box of the profile name If you set the time with time setting button the changed contents in the list can be checked G In case of deleting the information if you press th...

Page 29: ...t and button Creation button Edit button H To set the working schedule select the relevant time zone in the time schedule list after selecting the saved user to set the working schedule of the user If...

Page 30: ...ess the edit button after selecting the user to change in the list and then it is completed Caution Creation button is needed first once a month at least Since then the schedule changes of the relevan...

Page 31: ...rity designation Bed select button Room list Red part Bed list Red part Setting button Select all beds button User select button User list J After selecting the bed and room to set choose the relevant...

Page 32: ...he responsible bed of a nurse individually User select button Bed select button Whole bed list Edit button K After selecting the user to set choose the bed in charge Then press the edit button and it...

Page 33: ...ection form Time interval Bed selection button Interval set button Select all button Delete all button Setting button L After checking the bed number to set select the concurrence or not by pressing n...

Page 34: ...34 M It will be set at once with Select all Cancel all button www safemag ru www safemag ru...

Page 35: ...relevant bed with main receiver Designation in charge for bed function can be used if this process is preceded Set screen through main receiver Mark of main receiver confirmation Send button N In case...

Page 36: ...t will be saved in the server Set screen through smart phone Enter the number of main receiver Enter IP address Main receiver confirmation mark A To user the designation function for the bed in the sm...

Page 37: ...e server the record of user loading the time organization history press the relevant server IP and port number C During setting a smart phone confirmation mark of the main receiver is shown as uncheck...

Page 38: ...sting number in Before and correct the number in After and press OK Then the value will be changed 3 To change the bed number enter the room number and after pressing the asterisk button enter the bed...

Page 39: ...etting screen 2 Reset 1 This is the function to reset the power of bed connected with the main receiver 2 Press the OK button and Yes button Then you can reset the power of the bed www safemag ru www...

Page 40: ...40 Chapter 2 Configuration www safemag ru www safemag ru...

Page 41: ...iguration 1 Setting the environment In the mode of environment setting you can move to stand by screen and previous screen by pressing HOME or BACK button on the top of the screen www safemag ru www s...

Page 42: ...next button enter the new password again to verify whether the password you enter earlier is correct After clicking the complete button you can go back to the password changing mode Press the OK butto...

Page 43: ...nter the relevant IP address after pressing the screen to input if the window to input is marked II Call prix fixe setting Press the call prix fixe to select in the menu If call prix fixe input screen...

Page 44: ...the Okay button setting is saved III Call Alarm bell sound Press the call bell sound or alarm bell sound In case of telephone bell sound list screen of caller s location is displayed In case of bell...

Page 45: ...to save of the product can be checked SD card whole size of internal space to save and size of the saving space available are marked Language and keyboard The language marked in the equipment and sim...

Page 46: ...onnected with the entered time server rightly it is changed to the current time Synchronizing with server every time set at an interval of synchronization II Date and time setting manually Cancel the...

Page 47: ...The date form selection window is marked on a screen Press the form to set System Info Able to check the component installed in system and product firmware info I Checking component version Press the...

Page 48: ...48 Diagram z Product name nurse calling device z Line item JNS 70MN z Power source DC24V z Max current consumption 400mA www safemag ru www safemag ru...

Page 49: ...11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2011 12 104 www safemag ru www safema...

Reviews: