background image

 

23 

 

7

 

Appendix 

7.1.

 

Using the Owner mobile app 

Login 

 

 

1)

 

Enter  the  ID  and  password  that  you  registered 
to in the Wallpad 

2)

 

Press the "Login" button. 

3)

 

Enter your nickname and Press the 'OK' button. 

 

 

4)

 

In  the  home  screen,  you  can  select  "Call  Log", 
"Checking visitors", and "Setting". 

 

Summary of Contents for Wall PAD CIP-700MW

Page 1: ...1 Home Network User Manual PMN Wall PAD...

Page 2: ...ded from the screen saver 5 2 Home Display 6 3 Notice 7 4 Control 8 4 1 FCU Control 8 5 Application 10 5 1 Intercom 11 5 2 Security 14 5 3 Home History 16 5 4 ETC 17 6 Away Stay Mode 19 7 Appendix 23...

Page 3: ...rt name TFT LCD Speaker Emergency button Call guard station Door release button Call button Home Button Microphone Power Switch PoE PIR 1 Sensor_in 2 GND 3 VCC EM RS 485 1 TRX 2 TRX 3 GND DDL VCC OPTI...

Page 4: ...4 Display composition Buttons at the Bottom Go to Home Back Press the button...

Page 5: ...screen saver to go to the home screen 1 1 Information provided from the screen saver Today s weather information Indoor humidity Indoor temperature Notice It is not provided when there is no informati...

Page 6: ...Display Visitor Log Check recorded images of visitors Concierge Calling the guard station Away Away mode Stay Stay mode Notice Notice Apps The list of installed apps Emergency Panic alert Cameras CCT...

Page 7: ...7 3 Notice You can check the notices Notices...

Page 8: ...ating machines by pressing the power button of whole air conditioning heating 4 You can enable or disable all cold heater exit mode by pushing go out button of whole air conditioning heating 5 You can...

Page 9: ...off 4 Pressing the OFF button in the go out mode releases the go out mode The cold heating machine will return to the status before going out When you turn on off the power from away mode setting you...

Page 10: ...10 5 Application...

Page 11: ...Call refusal Cancel Door Open Save of Visitor image Call display can be displayed differently by each type of call from guard station and entrance Some equipment does not provide CID function Visitor...

Page 12: ...nce 1 Press Capture an image button while paging or calling 2 If successfully recorded the visitor s photos which are confirmed visitors on the home screen will be displayed Pick up the phone from Com...

Page 13: ...Security office and management office cannot see the user s image The guard video call is only available for products with video call cameras If you use the call transfer function during the guard sta...

Page 14: ...Guard station The emergency notice is processed in three steps such as On Off and Reset Emergency on 1 Emergency can be generated by pressing the emergency icon or by pressing the emergency button on...

Page 15: ...15 Password input...

Page 16: ...lete selected images You can see where the picture was taken with the icon My house Picture taken at my house Common entrance Images taken from an common entrance Out In case of go out Go out mode set...

Page 17: ...re to uncheck the images or Select all box 4 Touch Delete button to delete selected images 5 4 ETC Settings Settings Sign Up User registration 5 4 1 Sign Up User registration Edit Reset 1 Enter your I...

Page 18: ...18 initialize 1 If membership has been registered pressing the Reset button deletes the registered member information...

Page 19: ...19 6 Away Stay Mode Away mode Sraty mode...

Page 20: ...time 3 If you want to cancel away mode press CANCEL button Go Out mode set up 1 Delayed time for go out 3 Start away mode 2 Action item when going out If security mode is on away mode cannot be start...

Page 21: ...irm button to save Restore Go Out mode 1 Press Go Out mode button 2 When it appears on the password input screen enter the password and click the confirm button 3 If the passwords match go out mode wi...

Page 22: ...ttings 1 Check the security sensor to be set by pressing the Areas button 2 After settings press set and the burglar sensor in adjusted area will be started Burglar sensor settings The number of burgl...

Page 23: ...er mobile app Login 1 Enter the ID and password that you registered to in the Wallpad 2 Press the Login button 3 Enter your nickname and Press the OK button 4 In the home screen you can select Call Lo...

Page 24: ...e Doors management button 4 Press the button and the access key will be issued 5 If there is more than one key that has been issued you can move it by checking the left right page 6 The expiration dat...

Page 25: ...uest within 3 minutes 4 When the validity time has elapsed the authentication key is reissued 5 Press the Visitor management button 6 After the guest registers if you enter the authentication key Gues...

Page 26: ...26 The visitor access notice message When an owner and guests visit a push message is provided on the mobile Notification push messages is displayed as nickname entered you signed up...

Page 27: ...2 Using the Guest mobile app Login 1 Press the Visitor Sign in button 2 Enter Visitor Name ID Password Retype password 3 Press the Next button 4 Press the Login button when the registration is comple...

Page 28: ...28 5 Enter the nickname to use and Press the Confirm button...

Page 29: ...Enter the authentication key received from the owner 3 When the owner confirms and releases the access key the access key is displayed 4 The expiration date of the access key is displayed 5 If not re...

Page 30: ...enter or exit Door lock DDL setting Setting Manual Lock 1 Touch the keypad of the door lock DDL 2 Enter the password for the door lock Ex password 2580 3 Enter 7 Ex 2580 7 Setting Auto Lock 1 Touch th...

Page 31: ...AGE INPUT PoE DC 48V TELECOMUNNICATION AUDIO VoIP VIDEO H 264 LINE DISTANCE STANDARD UTP CAT 5e 70m FROM THE PSE TEMPERATURE 0 40 SPECIFICATION CPU Dual Core ARM Cortex A7 MEMORY 1G DDR3 RAM 512M 2 FL...

Page 32: ...32 INSTALLATION PACKAGE CONTENTS MONITOR FIXING WALL BRACKET WALL BRACKET MONITOR CIP 700MW CONNECTOR MANUAL 3P 1EA 2P 1EA M 3 x 6mm T 4 x 18mm MOUNTING SCREW 4EA SCREW 1EA...

Page 33: ...th the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harm...

Page 34: ...tions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device D claration de conformit IC Industrie...