Page 10
CONNECTING THE LIQUID PROPANE GAS CYLINDER
1.
Turn the oven burner valve OFF and make sure the oven is cool.
2. Turn the liquid propane cylinder valve OFF by turning clockwise until it stops.
3. Detach the regulator assembly from the cylinder valve by turning the quick
coupling nut counterclockwise.
4. Place dust cap for cylinder valve outlet whenever the cylinder is not in use.
NOTE:
1. The LP gas supply cylinder to be used must be constructed and marked in
accordance with the specifications for LP gas cylinder, U.S. Department of
Transportation (DOT) or the standard of cylinders, Spheres and tubes for the
Transportation of Dangerous Goods, CAN/CSA-B339
2. The cylinder supply system must be arranged for vapor withdrawal.
LEAK TESTING
GENERAL
Although the gas connections of the appliance are leak tested prior packing and
shipment, a complete test must be performed at the installation site.
Before each use, check all the gas connections for leak testing using the procedure
listed below. If the smell of gas is detected at any time, you should immediately stop
using and check the entire system for leaks.
BEFORE TESTING
Make sure all packing material has been removed from the appliance.
Make a solution of one part liquid detergent and one part water. You will need a spray
bottle, brush or rag to apply the solution to the fittings.
TO TEST
1.
Turn the burner valve OFF.
2. Turn the liquid propane cylinder valve on counterclockwise to open the valve.
3. Apply the soap solution to all gas fittings. Soap bubbles would appear where a
leak is present.
4. If a leak is present, immediately turn the gas supply OFF and tighten leaky
fittings.
5. Turn the gas back ON and recheck.
6. Should the gas continue to leak from any of the fittings, turn the gas supply OFF
and contact customer service.
SET UP & USE